65
EN
FORCING CYCLE PHASES
It is possible to force the program to go to any phase (Mixing/Rising/Storage) at any time during the
cycle
Press the
key for 4 seconds to go to the mixing phase
Press the
key for 4 seconds to go to the rising phase
Press the
key for 4 seconds to go to the storage phase
FORCING MIXING
When refreshing the natural yeast starter, the Force Rotation function can be activated at any time
by pressing the
key. The accessory will turn for 1 min 30 sec.
BOWL TEMPERATURE CHECK
Press the
+
keys at the same time at any point during the cycle.
ALARM DESCRIPTION
The message that appears on the display corresponds to an alarm situation, signalled by the symbol
and the buzzer going off.
Al A.2 TC1: Problem with the product temperature probe
Al A.3 TC2: Problem with the bowl temperature probe
Al A.4 MOT: Problem with the motor or inverter
Al A.5 ENE: Guard open or emergency button pressed
Al A.6 FRI: Problem with refrigerator unit
Al A.7 RES: Problem with heating unit
The signal on the display remains until the problem is resolved.