4.
Display and Keys
4.1 LCD Display
a.
25mm (1’’) 5 digits LCD with all functions and units.
b.
:
Wireless signal: It shows up when the signal is stable; It
disappears when no signal detected; Flashing when the signal is weak.
c.
:
Battery Voltage,
:
Full,
:
Low
,
:
Empty
d.
PEAK
:
Current value is in Peak Hold value (maximum value).
e.
MEM
:
Appears once when Parameter or Calibration value is stored
to memory. Appearing in the display means the current value is added
to Accumulated data.
f.
STB:
Stable Status.
g.
KN
: “kilo-Newton”,
N
:
“Newton”. Tare status “N” will flash.
h.
t
:
“Ton”
i.
lb
:
“Pound”
j.
kg
:
“Kilogram ”
4.2 Keys
a.
ON/OFF key
•
Press “
ON/OFF”
key to turn on the dynamometer.
•
At ON status
,
pressing “
ON/OFF”
key for 1 second, the
dynamometer will turn off.
b.
ZERO key
When the dynamometer at no load is showing reading other
than zero, pressing this key will zero the reading.
c.
UNIT key
Pressing the UNIT key, the scale will switch its unit and the screen
will display the following units in order: “kg”
→
“lb”
→
“N”
→
“kN
”→ “
t
”→
“kg”.
d.
PEAK key
6
|
ANYLOAD OCSD Wireless Dynamometer Operations Manual (V1904)