![Anyload OCSD Series Operation Manual Download Page 12](http://html1.mh-extra.com/html/anyload/ocsd-series/ocsd-series_operation-manual_2948868012.webp)
Press
【
ENTER
】
to
confirm
〖
2 OFF
〗
The screen will display 2 OFF. If
already set, it will display the set
value.
Press
【
ZERO
】
to
choose
〖
2 HI
〗
or
〖
2 LO
〗
There are 3 choices: 2 OFF means
you will not set a set point; 2 HI
means the indicator will alarm
when load exceeds the set value; 2
LO means the indicator will alarm
when load is smaller than the set
value.
Press
【
ENTER
】
to
confirm
〖
01200
〗
The screen should display 01200 if
you set it to 1200.
Press
【
ZERO
】
and
【
TARE
】
to change
value
〖
03000
〗
Set “2 LO” or “2 HI” Value.
e.g.3000kg
If you will not set a set point, just press the
【
ENTER
】
key until it
displays the next function.
6.
Wireless Indicator Operation Guides
P180
P380
P580
DESCRIPTION/FUNCTION
Push
button
switch
ON/OFF
ON &
OFF
Pressing ON/OFF will turn on or turn off the
indicator.
【
ZERO
】
When the screen displays reading other than
zero during weighing mode, pressing the
【
ZERO
】
will return the scale to zero.
【
TARE
】
1.
When there is tare weight such as a
container and the reading is stable,
pressing this key will display “0” and
“N” indicator will flash.
2.
Putting the object(s) into the
container, the dynamometer will
display the net weight.
3.
If the object(s) and container are
removed, the dynamometer will display
a negative value.
4.
During Parameter Settings, it can also
be used as a directional key.
11
|