164
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
26 Enable EtherNet/
IP QuickConnect
a
Get
BOOL
False
Value:Meaning:
True EtherNet/IP QuickConnect function-
ality enabled.
False EtherNet/IP QuickConnect function-
ality disabled.
29 Ignore Sequence
Count Check
Get
BOOL
False
Setting this attribute to “true” makes the
module ignore the Sequence Count Check
for consumed Class 1 data.
This means that all data, not just changed/
new data, received from the Originator, will
be copied to the application.
Copying all data and not just changed data
is a violation of the CIP specification. It will
also affect the performance of the module.
Use precaution when setting this flag to
“true”.
HMS will do NO performance measure-
ments and states NO guarantees about how
performance will be affected when copying
all data.
30 ABCC ADI Object
Number
Get
UINT16
00A2h
This attribute either changes the object num-
ber of the ADI Object or disables the ADI
Object (see page 83). Valid object numbers
are within the vendor specific ranges (0064h
- 00C7h and 0300h - 04FFh). Any other
value will disable the ADI object.
31 Enable DLR
Get
BOOL
True
True = DLR functionality enabled
False= DLR functionality disabled
a. If the module is configured to use EIP QuickConnect functionality, the EDS file has to be changed. As the EDS file
is changed, the identity of the module has to be changed and the module will require certification, see “Conform-
ance Test Guide” on page 12.
# Name
Access Type
Default Value
Comment