Command Details: Send
Category
Extended
Details
Command Code.:
17h
Valid for:
Instance
Description
This command sends data on a connected socket. Message segmentation may be used to send up to 1472
bytes (see “Message Segmentation” on page 189).
NON-BLOCKING mode:
If there isn’t enough buffer space available in the send buffers, the module will respond with er-
ror code 0006h (EWOULDBLOCK)
BLOCKING mode:
If there isn’t enough buffer space available in the send buffers, the module will block until there
is.
• Command Details
Note:
To allow larger amount of data (i.e. >255 bytes) to be sent, the command data may be
segmented (see “Message Segmentation” on page 189).
• Response Details
Field
Contents
Notes
CmdExt[0] (reserved)
(set to zero)
CmdExt[1] Segmentation Control
see “Command Segmentation” on page 190
Data[0...n] Data to send
-
Field
Contents
Notes
CmdExt[0] (reserved)
(ignore)
CmdExt[1]
Data[0]
Number of sent bytes (low)
Only valid in the last segment
Data[1]
Number of sent bytes (high)