SELECTING LOCATION FOR THE DRYER
Locate the grain dryer as a part of the farm's centre of operations, taking into account possible traffic, noise and
dust problems. Construct the roads in a manner enabling them to be trafficked with a full trailer round the year.
If possible, locate the heater on the facade side of the building. When selecting location for the heater, observe
in particular that it requires large amounts of clean air. The suction opening of the heater must be located as far
from the outlet air pipes as possible, on the other side of the building. If you have doubts concerning the location,
negotiate in advance with the local building and road authorities, and the fire chief.
The distance from the grain dryer to the land of the neighbour shall be at minimum 15 m, to the neighbouring
building 20 m, to your own residential building15 m, and to an outbuilding 12 m. (The minimum distance to your
own buildings may vary from municipality to municipality, depending on how the new regulations are being locally
interpreted). For dryers of category P2, the required distances may be shorter. Under certain conditions, a package
dryer may fall into category P2. Consult the local fire chief or building supervisor for detailed instructions.
FOUNDATION
GROUND PRESSURE
When selecting suitable founding method for your dryer, apply the following base values for different soil types:
Moraine
0,4 – 0,8 MN/m2
Gravel
0,2 – 0,6 MN/m2
Sand
0,15 – 0,5 MN/m2
Fine sand
0,1 – 0,4 MN/m2
Clay and fine silt:
- soft (easy to work)
0,025 MN/m2
- tough (hard to work)
0,050 MN/m2
- solid (extremely hard to work)
0,1 MN/m2
If you consider that the load-bearing capacity of the soil is difficult to determine, assign a specialist or order a ground
survey. It is often a good idea to establish the form of the rock by means of a ground survey or a test excavation.
Typically, the ground pressure caused by a dryer is 0.5–2.0 kg/cm
2
when the foundation is of raft type.
Summary of Contents for Vacboost M13
Page 17: ...Antti Teollisuus Oy 17 408111 03 2019 Vacboost M13 C 255 C 255_malli ...
Page 18: ...Antti Teollisuus Oy 18 408111 03 2019 Vacboost M13 C 320 C 320_malli ...
Page 19: ...Antti Teollisuus Oy 19 408111 03 2019 Vacboost M13 C 365 C 365_malli ...
Page 20: ...Antti Teollisuus Oy 20 408111 03 2019 Vacboost M13 C365 E A1500_3D C365 E A1500 ...
Page 21: ...Antti Teollisuus Oy 21 408111 03 2019 Vacboost M13 C 410 E 700_3D C410 E 700 ...
Page 22: ...Antti Teollisuus Oy 22 408111 03 2019 Vacboost M13 C410 E 1000_3D C410 E 1000 ...
Page 23: ...Antti Teollisuus Oy 23 408111 03 2019 Vacboost M13 C 410 E A1500_3D C410 E A1500 ...
Page 25: ...Antti Teollisuus Oy 25 408111 03 2019 Vacboost M13 ...
Page 32: ...Antti Teollisuus Oy 32 408111 03 2019 Vacboost M13 C365 uunin putket Heater pipes C365 ...
Page 33: ...Antti Teollisuus Oy 33 408111 03 2019 Vacboost M13 D800 putket D800 pipes ...
Page 35: ...Antti Teollisuus Oy 35 408111 03 2019 Vacboost M13 Puhallinteline asentaminen ...
Page 64: ...Antti Teollisuus Oy 64 408111 03 2019 Vacboost M13 ...