51
Select IN
IN mode
Select OUT
OUT mode
(3) MODE is set up when “ENT” key is pressed after the select.
eq \x(Up/Down) eq \x(ENT) eq \x(Up/Down)
(Select IN) ------ eq \x(ENT)
Set IN mode
(Select OUT)
eq \x(ENT) ----- Set OUT mode
Stop the alarm tone
When the alarm sounds, press any key to stop. But the guard zone function is still working, the alarm may
sounds again. To "OFF" the guard zone function, select "OFF" from GZ menu.
5.5.2.3 Shifting display in specific direction (OFF-C)
Displaying the location specified by the cross cursor as the vessel's location.
(1) Select OFF-C from the pull-down display items using up-down cursor key, and press the "ENT" key.
(2) When the ON/OFF sign is displayed beside the OFF-C item, select ON with the up-down cursor keys and
press the "ENT" key.
(3) OFF-C is displayed at the upper right and "SET OFF CENTER POINT" at the bottom of the screen, and
setting is ready to be entered. Move the cross cursor with the cursor keys to move the ship’s to the
intended location, and press the "ENT" key. The ship’s location will be displayed at the cursor's location.
The display at the upper right will be normalized from the reverse state, which indicates that the "OFF-C"
state is entered.
(4) To cancel “OFF-C” function, either select OFF in (2)
eq \x(Up/Down) eq \x(ENT) eq \x(Up/Down)
(Select OFF-C)
(Select ON)
eq \x(ENT)eq \x(Left/Right)&eq \x(Up/Down)eq
\x(ENT)
Set OFF-C
(Select OFF)
eq \x(ENT) ------------------------------
Cancel OFF-C
Note: VRM2 and EBL2 do not follow the OFF-C function while floating.
The function operates only on PPI screen.
5.5.2.4 Setting of the SLEEP function(SLEEP)
This function sends a 30-second-transmissions during pre-fixed hours. After a transmission, a power-saving