35
(IN or OUT) is to be set in the menu.
Note: Please refer to "5.5.2.2 Guard Zone (GZ)".
(1) When the "GZ" key is pressed, the present mode setting will be displayed on the left side of the screen as GZ IN.
A small cross cursor for setting the guard zone will be displayed at the screen center while "SET CENTER
POINT" is displayed at the bottom, activating a guard zone setting state.
(2) Use the up-down/left-right cursor keys to move the cross cursor to the center of the warning zone to be set, and
press the "ENT" key.
(3) From the cross cursor position set in (2) above as the center, expand the guard zone in the direction of the distance
with the up cursor key and in the direction of the angle with the right cursor key, thus making the form of a fan.
To make the warning zone smaller, operate the down cursor key (in the direction of the distance) and the left
cursor key (in the direction of the angle).
(4) After the setting the guard zone, finish by pressing the "ENT" key.
Press the GZ key twice to cancel the guard zone function.
eq
\x(GZ)
eq
\x(Up/Down)&eq
\x(Left/Right) eq \x(ENT) eq
\x(Up/Down)&eq \x(Left/Right) eq \x(ENT)
Setting completed
(Setting the center of GZ)
(Setting the scope of GZ)
eq \x(GZ) -----------------------------------------------------------------
Canceling GZ
Stop the alarm tone
Press the "MENU" key or "ENT" key during the alram tone sounds, alarm tone will stop.
note: Set the mode (IN or OUT) at the "GZ MODE" of the "PRESET2" function in the "CUSTOM" menu of the "SETUP"
Set the alarm level (IN or OUT) at the "GZ LVL" of the "PRESET2" function in the "CUSTOM" menu of the
"SETUP"
5.4.14 Off Center (OFF-C)
Displaying the location specified by the cross cursor as the ship's location
Note: Please refer to "5.5.2.3 Shifting display in specific direction (OFF-C)".
(1) When the "OFF-C" key is pressed, OFF-C is displayed at the upper right and "SET OFF CENTER POINT" at the
bottom of the screen, and setting is ready to be entered.
(2) Move the cross cursor with the cursor keys to move the ship to the intended location, and press the "ENT" key.
The ship's location will be displayed as the cursor's location. OFF-C is displayed at the upper right , which
indicates that the "OFF-C" state is entered.
(3) To cancel "OFF-C"function, press the "OFF-C" key.
(a) To conduct the setting
eq
\x(OFF-C) ------------------------------------eq \x(Up/Down & Left/Right)eq
\x(ENT) Conduct Off Center to exit the adjustment state.
Note: VRM2 and EBL2 do not follow the OFF-C function
while floating.
The function operate on PPI screen only.