3
Network Master Pro MT1040A: Main Frame
The Network Master Pro MT1040A is a multiplatform designed for field testing that is configured using a combination of transport and optical. The
Main Frame controls the test modules which can be changed freely to any custom configuration matching the users testing requirements.
Network Master Pro MT1040A Main Frame
9-inch active TFT display and touch screen
Power switch
AUX (D-SUB 15 pin)
USB
Mini-B
USB A
DC Input (19 Vdc)
Ethernet Service Interface
Clock Input
MT1040A Main Unit
Model/Order No.
Name
MT1040A
Network Master Pro
Standard Accessories
MT1040A-006
High Power Supply*
1
:
1 pc
Line Cord*
2
:
1 pc
B0745A
Softcase:
1 pc
B0771A*
3
MT1040A Rear Panel kit:
1 pc
G0418A
AC Adaptor:
1 pc
G0413A
Li-ion Battery:
2 pcs
W4039AE
Quick Reference Guide:
1 pc
Z1746A
Stylus:
1 pc
Z2077A
Utilities ROM:
1 pc
Z2082A
Handle:
1 pc
Software Option*
4
Model/Order No.
Name
MT1040A-003*
5
Connectivity for WLAN/Bluetooth
MT1040A-011
Site Over Remote Access Connect
Option for Two Transport Modules*
6
Model/Order No.
Name
MT1040A-020
Activate for 400G Dual/100G Quad Option
Standard Accessories
G0419A
AC Adapter (400 W)
*
1: The presence of the MT1040A-006 option can be recognized at the top right
of the front panel. To retrofit it, please contact sales representative.
Without MT1040A-006 With in MT1040A-006
*
2: One line cord is attached to the area to shipment.
*
3: Composed of B0720A, B0730A, B0731A, B0740A and B0741A.
*
4: These options can be retrofitted.
The Model/Order No. of retrofit options is “-3**”.
Example
MT1040A-003 Connectivity for WLAN/Bluetooth becomes MT1040A-303
Connectivity for WLAN/Bluetooth Retrofit.
When retrofitting an option, please either specify one of the following media
along with the relevant option, or Web download.
Z1849A: DVD-ROM for Retrofit Options
Z1850A: USB Stick for Retrofit Options
*
5: WLAN is available for certified countries and regions including USA, Japan and
EU countries. Please visit the Anritsu web site for updated information.
*
6: Can be added to main unit in which MT1040A-006 already installed. However,
battery operation is not possible when installing two transponder modules
together.
Module Configuration
2U
3U
4U
5U
400G (QSFP-DD) Multirate Module MU104014A
400G (OSFP) Multirate Module MU104015A
100G Multirate Module MU104011A
10G Multirate MU100010A
100G Multirate MU100011A
1310/1550 nm SMF MU100020A
1310/1550/850/1300 nm SMF/MMF MU100021A
1310/1550/1625 nm SMF MU100022A
1310/1550/1650 nm SMF MU100023A
Summary of Contents for Network Master Pro MT1040A
Page 34: ...34 Note...
Page 35: ...35 Note...