27
<MU100010A>
To add a new protocol option to a previously purchased MU100010A, choose the required option from the following list.
The MU100010A serial number is required to make the purchase.
Adding MU100010A Protocol Option
Bit Rate
Less than 5G
From 6G to 10G
Transport Technology
No. of
Measurement
Ports*
1
2 (Dual Channel)
1 (Single Channel)
2 (Dual Channel)
Ethernet
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream, OAM, SyncE, MPLS,
MPLS-TP, Multistage VLAN, PBB, Ping/Traceroute, Cable Tests, In-band Control,
Auto discovery, Path-through
MU100010A-301
Up to 2.7G Dual Channel
Retrofit
MU100010A-311
Ethernet 10G Single Channel
Retrofit
MU100010A-312
Ethernet 10G Dual Channel
Retrofit
TCP Throughput Test (RFC 6349, iPerf)
MU100010A-320
TCP Throughput Retrofit
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
MU100010A-301
Up to 2.7G Dual Channel
Retrofit
MU100010A-311
Ethernet 10G Single Channel
Retrofit
MU100010A-312
Ethernet 10G Dual Channel
Retrofit
OTN*
2,
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test, O.182 Test,
Overhead Editing/Capture, TCM Monitoring/Generation, Tributary Scan
MU100010A-301
Up to 2.7G Dual Channel
Retrofit
MU100010A-351
OTN 10G Single Channel
Retrofit
MU100010A-352
OTN 10G Dual Channel
Retrofit
ODU Multiplexing Addition*
3
MU100010A-361
ODU Multiplexing Retrofit
ODU Flex Addition*
4
—
MU100010A-362
ODU Flex Retrofit
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement,
Monitoring using Passthrough
MU100010A-371
CPRI/OBSAI Up to 5G
Dual Channel Retrofit
MU100010A-372
CPRI/OBSAI 6G to 10G
Single Channel Retrofit
MU100010A-373
CPRI/OBSAI 6G to 10G
Dual Channel Retrofit
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
MU100010A-302
FC 1G 2G 4G Dual Channel
Retrofit
MU100010A-391
FC 8G 10G Single Channel
Retrofit
MU100010A-392
FC 8G 10G Dual Channel
Retrofit
SDH/SONET, PDH/DSn
PDH/DSn Test, Tw-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/Generation,
Pointer Event Generation, Tributary Scan
MU100010A-301
Up to 2.7G Dual Channel
Retrofit
MU100010A-381
STM-64 OC-192
Single Channel Retrofit
MU100010A-382
STM-64 OC-192
Dual Channel Retrofit
*
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
*
2: When using the OTN function, the channel can be used as client signal mapped to OTN. For example, when mapping STM-64/OC-192 to OTU2, both the
MU100010A-351/352 (for physical port) and the MU100010A-381/382 (for client signal) are required.
*
3: When the ODU Multimapping option is installed, OTN multistage mapping measurements are supported.
This one option supports both single channel and dual channel.
*
4: When the ODU Flex option is installed, since transport is over OTN networks, mappings based on used ODU Flex standard can be measured.
This one option supports both single channel and dual channel.
Additional Purchases
Adding New Options to Previously Purchased MT1040A
Summary of Contents for Network Master Pro MT1040A
Page 34: ...34 Note...
Page 35: ...35 Note...