24
Additional Purchases
Adding New Options to Previously Purchased MT1040A
Confirm the serial numbers of the MT1040A, MU104014A/MU104015A/MU104011A and MU100010A/MU100011A.
4-1 Adding Test Protocols for Transport Module
When adding options, please either specify one of the following media along with the relevant option, or Web download.
Model
Name
Z1849A
DVD-ROM for Retrofit Options
Z1850A
USB Stick for Retrofit Options
In addition, when purchasing multiple retrofit options at one time, they are all installed using the same media.
<MU104014A>
To add a new protocol option to a previously purchased MU104014A, choose the required option from the following list.
The MU104014A serial number is required to make the purchase.
MU104014A
Bit Rate
10G or less
16G or 25G
40G or 100G
200G or 400G
Transport Technology
No. of Measurement
Ports*
1
2 (Dual Channel) 2 (Dual Channel) 1 (Single Channel) 2 (Dual Channel) 1 (Single Channel)
Ethernet
IPv4/IPv6, Y.1564, IEEE 1588 v2, RFC 2544, BER, Multistream,
OAM, SyncE, MPLS, MPLS-TP, Multistage VLAN, PBB,
Ping/Traceroute, In-band Control, Auto discovery,
Y.1564 (100G), Reflector
MU104014A-312
Ethernet up to 25G Dual Channel Retrofit
MU104014A-313
Ethernet 40G
Single Channel Retrofit
MU104014A-314
Ethernet 40G
Dual Channel Retrofit
MU104014A-331
Ethernet 200G
Single Channel Retrofit
MU104014A-315
Ethernet 100G
Single Channel Retrofit
MU104014A-316
Ethernet 100G
Dual Channel Retrofit
MU104014A-333
Ethernet 400G
Single Channel Retrofit
Pass-through (10G), Channel Stat (10G)
MU104014A-312
Ethernet up to 25G
Dual Channel Retrofit
—
—
—
—
TCP Throughput Test (RFC 6349, iPerf,10G)
MU104014A-320
TCP Throughput
Retrofit*
2
—
—
—
—
eCPRI/RoE (IEEE1914.3)
IPv4/IPv6, BER, VLAN, SyncE, IEEE 1588 v2, E-OAM
MU104014A-312
Ethernet up to 25G Dual Channel Retrofit
MU104014A-313
Ethernet 40G
Single Channel Retrofit
MU104014A-314
Ethernet 40G
Dual Channel Retrofit
—
MU104014A-315
Ethernet 100G
Single Channel Retrofit
MU104014A-316
Ethernet 100G
Dual Channel Retrofit
—
OTN
Errors/Alarms, Error Performance/Delay/APS Test, FEC Test,
O.182 Test, Overhead Editing/Capture, TCM Monitoring/
Generation, Tributary Scan
MU104014A-352
OTN up to 10G
Dual Channel Retrofit
—
MU104014A-353
OTN 40G
Single Channel Retrofit
MU104014A-354
OTN 40G
Dual Channel Retrofit
—
—
MU104014A-355
OTN 100G
Single Channel Retrofit
MU104014A-356
OTN 100G
Dual Channel Retrofit
—
ODU Multiplexing Addition
MU104014A-363
ODU Multiplexing/
Multi Stage Retrofit*
3
—
MU104014A-363
ODU Multiplexing/Multi Stage Retrofit*
3
—
CPRI/OBSAI
CPRI/OBSAI L1: Level/Bit Rate/Frequency deviation Measurement,
Alarms/Errors Detection, Unframed BER
CPRI/OBSAI L2: Link Status Monitoring, Alarms/Errors Detection,
Framed BER Measurement, RTD Measurement,
Monitoring using Passthrough
MU104014A-374
CPRI/OBSAI up to 25G Dual Channel Retrofit
—
—
—
Fibre Channel
Performance Test, Signal Generation/Monitoring, Latency, BER,
Line Alarm/Error Monitoring
MU104014A-392
FC up to 16G Dual Channel Retrofit
—
—
—
SDH/SONET
Two-Way Monitoring/Mapping, Errors/Alarms,
Error Performance/Delay/APS Test, Header Monitoring/
Generation, Pointer Event Generation, Tributary Scan
MU104014A-382
SDH/SONET up to
10G Dual Channel
Retrofit
—
MU104014A-384*
4
STM-256/OC-768 Client Signal Retrofit
—
*
1: The channel is not related to the physical port position. The user can freely choose either of the two physical ports assigned to the option via software.
For a dual channel setup, the two different ports of one protocol can operate simultaneously, or two different single channel options can operate simultaneously.
*
2: Requires to MU104014A-012.
*
3: Requires that at least one of the following option is installed: MU104014A-052, MU104014A-053, MU104014A-054, MU104014A-055, MU104014A-056.
*
4: MU104014A does not have a physical interface of the option. The option is required for client signal mapped in the OTN.
Summary of Contents for Network Master Pro MT1040A
Page 34: ...34 Note...
Page 35: ...35 Note...