ArcSource 96 Integral (RGBW)
15
6.1 Fixture Address
Use this menu to set the DMX address of the fixture or set the fixture as a Master (Slave).
dM.Ad.
---
DMX addressing
. Select this submenu to set a DMX start address.
To set a DMX address.
1.
Use the UP/DOWN buttons to find “
A001
“ menu.
2.
Press the ENTER button.
3.
Use the UP/DOWN buttons to select desired start address.
4.
Press the ENTER button to confirm the choice.
MA.SL. --- Master/slave addressing
. Select this submenu to set the fixture as a master or slave. Option "
d.AbL
"
deactivates master/slave setting. This option does not function at wireless operation.
To set a fixture as a master or slave.
1.
Use the UP/DOWN buttons to find “A001“ menu.
2.
Press the ENTER button.
3.
Use the UP/DOWN buttons to select “
MA.SL.
“ item.
4.
Press the ENTER button.
5.
Use the UP/DOWN buttons to select either master (MASt) or slave (SLA)
6.
Press the ENTER button to confirm the choice.
Note
: After switching on, the ArcSource 96 Integralwill automatically detect whether DMX 512 data is received or
not.
If there is no data received at the DMX input, the display will start to flash with actually set address.
6.2 Fixture information
Use this menu to read useful information about the fixture status.
To display desired information.
1. Use the UP/DOWN buttons to find the “ InFo“ menu.
2. Press the ENTER button.
3. Use the UP/DOWN buttons to select the required menu item.
4. Press the ENTER button to confirm the choice.
Po.ti.
---
Power On Time.
Use the menu item to read the number of operation hours for each LEDs operating
mode.
FuLL
---Max light output from the fixture.
totL
- the function shows the total number of the operation hours in the “FuLL” mode since the
ArcSource 96 Integral has been fabricated.
rESEt
- the function shows the number of the operation hours that the ArcSource 96 Integral
has been powered on in the “FuLL” mode since the counter was last reset. In order to reset this
counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press
the ENTER button.
EcO
---Economical mode.
totL
- the function shows the total number of the operation hours in the “EcO” mode since the
ArcSource 96 Integral has been fabricated.
rESEt
- the function shows the number of the operation hours that the ArcSource 96 Integral
has been powered on in the “EcO” mode since the counter was last reset. In order to reset this
counter to 0 you have to press and hold the UP and DOWN buttons and at the same time press
the ENTER button.