background image

ArcSource 96 Integral (RGBW) 

 

16 

 

DM.In.

---

DMX values

. Select this function to read DMX values of each channel received by the fixture. 

 

 

 

 

 

 

tEMP

 ---

 Fixture Temperatures.

 Select this menu to read the temperatures of the fixture: 

 

 

Cur.t. 

 --- the current temperature of the fixture inside. 

 

 

Hi.tE.

 - the menu item shows the max. temperatures of the fixture inside since 

 

 

the ArcSource 96 Integralhas been fabricated.  

 

 

rSEt

 --- the menu item shows the maximum temperatures of the fixture inside since the counter 

 was last reset. In order to reset this counter to 0 you have to press and hold the UP and DOWN 
 buttons and at the same time press the ENTER button.  

Measuring points: 
 

 

LEdS

.--- the temperature of the LEDs module. 

 

 

boAr.

 --- the temperature on the PCB in the fixture base. 

 

Note: The ambient temperature should not exceed 40°C. 
The temperatures can be displayed in either °C or °F units - see option “tEM.U“ in the menu “Pers“.     

 

 

VErS.

 ---

Software Versions.

 Select this function to read the software version of the fixture processor. 

 

 

  

 

 

 

6.3 Personality 

 

Use this menu to modify the ArcSource 96 Integraloperating behaviour. 

 

DM.Pr.

 --- 

DMX preset

. Select this menu item to set a desired DMX mode. Please refer to the chapter "DMX 

protocol" for detail description of each DMX mode. 
 

 

 

DiSP.

 --- 

Display adjusting

. This function allows you to change the display settings. 

 

 

d.On

 --- this function allows you to keep the display on or to turn off automatically 2 minutes  

 

 

 

after last pressing any button on the control panel. 

 

 

 

d.Int.

 --- select this function to adjust the display intensity (30-min.,100-max.).  

turn

 ---  select this function to turn the display by 180°. 

 

tEM.U. 

 --- 

Temperature Unit.

 Use this menu in order to display the fixture temperatures in desired units: °C or °F. 

 

bALA --- Balance

 Use this menu item to enable (On) or disable (Off) the white balance which is set in the “White 

colour balance“ menu below. I f this function is set off, the ArcSource 96 Integral will use maximum values (255) of 
saturation for red, green and blue colour. This function has to be set on before adjusting a white balance. 
 

C.bAL. 

--- 

White Colour Balance. 

The menu gives access to the setting of the white balance. 

To set white colour balance. 

1.

 

Use a DMX controller or the “ Man.C.“ menu to set all LEDs on max. saturation. 

2.

 

Use the UP/DOWN buttons to find the “ Pers.“ menu. 

3.

 

Press the ENTER button. 

4.

 

Use the UP/DOWN buttons to select the “C.bAL“menu. 

5.

 

Press the ENTER button and the “rEd“ item will appear on the display. 

6.

 

Press the ENTER button and use the UP/DOWN buttons to set new max. value for the red LEDs. 

7.

 

Press the ENTER button to confirm the choice.  

8.

 

Use the UP/DOWN buttons to select next colour,  the “GrEn“. 

9.

 

Repeat steps 6-7 for this channel. 

10.

 

Use the UP/DOWN buttons to select the last colour,  the „bLuE“ and repeat steps 6-7 for this colour. 

 

Summary of Contents for ArcSource 96 Integral

Page 1: ...Version 1 6...

Page 2: ...Master slave connection 8 3 6 Stand alone operation 8 4 ArcSource 96 Integral RGBCW DMX protocol 10 5 Control menu map 12 6 Fixture menu 14 6 1 Fixture Address 15 6 2 Fixture information 15 6 3 Person...

Page 3: ...y Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock...

Page 4: ...he fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not...

Page 5: ...rientation on a wall truss without altering its operation characteristics The mounting bracket allows to adjust desired fixture position The 3 mounting slots in the mounting bracket have a diameter of...

Page 6: ...fixture can also stand directly on a flat surface by means of the removable stand For overhead placing you must use safety rope with screw on carbine Pull the safety rope through the mounting bracket...

Page 7: ...nnection The power cores are coloured according to the following table Core Connection Plug Terminal Marking Black Live L Blue Neutral N Yellow Green Earth This device falls under class one and must b...

Page 8: ...output of the last fixture with a 120 Ohm resistor wired betwen data and data in order to ensure the proper transmission on the data link 3 5 Master slave connection To build a master slave chain Con...

Page 9: ...he same in all slaves and depends on the master s choice menu St AL Every fixture runs its program repeatedly starting the program step No 1 when requested by the master Example If the slave fixture h...

Page 10: ...rtional 4 4 0 255 White LEDs LED array 1 White LEDs saturation control 0 100 proportional 5 5 0 255 Red LEDs LED array 2 Red LEDs saturation control 0 100 proportional 6 6 0 255 Green LEDs LED array 2...

Page 11: ...0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Shutter Strobe both LED arrays Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow...

Page 12: ...Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti FuLL totL rSEt EcO totL rSEt DM In rEd1 0 255 F dim 0 255 tEMP Cur t boAr LEdS Hi tE boAr...

Page 13: ...l 4 Menu Level 5 Menu Level 6 tEM U C F bALA On Off C bAL rEd 0 200 255 GrEn 0 255 bLuE 0 237 255 Stor LOAd FuLL EcO In Po rEd1 0 255 F dim 0 255 Stor dFSE MAn M PrE C rEd1 rE 01 rE 03 dimr di 01 di 0...

Page 14: ...to your needs obtain information on its operation test its various parts and lastly program it if it has to be used in a Stand alone mode The four control buttons on the front have the following funct...

Page 15: ...Fixture information Use this menu to read useful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the...

Page 16: ...you to change the display settings d On this function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int select this fun...

Page 17: ...ture channels 1 Use the UP DOWN buttons to find Man C menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired effect channel List of control channels rEd1 red LEDs saturations array1...

Page 18: ...time the time taken by the step s channel status to reach the desired level and a step time the total time occupied by the step in the program E g If F tim 5 second and S tim 20 second effects will g...

Page 19: ...The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 if you want to use a serial port of PC Robe Un...

Page 20: ...us is being displayed in the Info Box window When the update is finished the line with the text The fixture is successfully updated will appear in this window and the fixture will reset with the new s...

Page 21: ...OR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIPTION DEVICE_HOURS Please see the Robe Universal Interface user manual...

Page 22: ...use Robe Universal Interface WTX Please see the Robe Universal Interface WTX user manual to get more information about this product To link the fixture with DMX transmitter The fixture can be only lin...

Page 23: ...nels Full mode Eco mode 87 000 100 000 Three LED channels Full mode Eco mode 82 000 94 000 All LED channels Full mode Eco mode 76 000 87 000 L70 70 maintenance of initial lumen output in hours Electro...

Page 24: ...00 Connection Power data cable Li9YCHY Cable 3xAWG16 1x 2xAWG24 Shielded and Jacketed junction box Rigging Via mounting bracket Temperatures Maximum ambient temperature 40 C Maximum housing temperatur...

Page 25: ...ral RGBW 25 Weight 11kg Removable floor stand Weight 1 2 kg Junction box Protection factor IP 67 fixture IP 66 junction box Included items 1 x ArcSource 96 ArcSource 96 W 1 x Junction box Junction box...

Page 26: ...No 10980070 Eggcrate top hat module in silver colour without lenses No 10980093 Top hat in silver colour No 10980079 Half top hat in silver colour No 10980080 Flash cable RS232 DMX No 13050624 Note B...

Page 27: ...ressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations...

Page 28: ...ArcSource 96 Integral RGBW 28...

Reviews: