ArcSource 96 Integral (RGBW)
7
3.3 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulation.
ArcSource 96 Integral.
The ArcSource 96 Integral is equiped with with a 5-cored power/data cable. The 3 cores serve for the power
supply and next 2 shielded cores are intended for DMX connection.
The power cores are coloured according to the following table.
Core
Connection
Plug Terminal Marking
Black
Live
L
Blue
Neutral
N
Yellow/Green
Earth
This device falls under class one and must be grounded!
The data cores (DMX) are coloured according to the table:
Core
Connection
Brown
Data +
White
Data -
Shielding
Data ground
The power/data cable is connected to a junction box as shown on the picture below.
ArcSource 96 Integral /W.
The wireless version of the ArcSource 96 Integral is equiped with with a 3-cored power cable.
The power cores are coloured according to the following table.
Summary of Contents for ArcSource 96 Integral
Page 1: ...Version 1 6...
Page 28: ...ArcSource 96 Integral RGBW 28...