4.2. Mounting the ArcPixel Power-CE
The ArcPixel Power-CE should be be placed on a non-flammable flat surface in any orientation and fixed by
the four screws.There are four mounting holes of a dimension of 5x7 mm in housing of the driver. Ensure that
installation place is enough ventilated.
1-Screws
2- flat surface
3-mounting holes
4.3. Connecting ArcPixes-CE
Connect ArcPixes to the LED outputs of the ArcPixel Power-CE. The first ArcPix in the ArcPix chain can be
connected to the screw terminal board on the ArcPixel Power-CE either via connection box or via customized
cable length (has to be specified at order). Maximum length between the ArcPixel Power-CE and the last ArcPix
must not exceed 100 metres. For larger installation, the ArcPixel Power-CE should be connected to the Robe
Media Server which allows automatic pixel mapping and full control of the ArcPixes modules.
Placing ferrites
The ferrite CSA19/9.4/29-4S60-EN (P/N 13051312) with one turn of the flat cable has to be placed on the
cable at each ArcPix output of the ArcPixel Power-CE, and this ferrite (without cable turn - cable goes directly
through ferrite, ferrite cover is snapped only) has to be placed after each thirtieth ArcPix in the ArcPix line (e.g.
100 ArcPixes per output = 3 ferrites in a line + 1 ferrite with a cable turn at the ArcPix output). You should count
100mm of the cable length per one cable turn on ferrite.
The ArcPix line ferrites (between ArcPixes) have to be placed on the flat cable before mounting of ArcPixes on
an installation surface.