18
- Robe Universal Interface (if you want to use an USB port of PC)
Note1. Software update should execute a qualified person.If you lack qualification, do not try the update
yourself and ask for help your ANOLIS distributor.
Note 2. IP address, and settings in the menu " Personality" will be set to their default values.
To update software in the fixture:
1
.Installation of the Software Uploader file (DSU_device name_time identifier):
1
.
The Software Uploader file for is available from the ANOLIS web site at WWW.anolis.cz.
2. Make a new directory ( e.g. ANOLIS_Uploader) on your hard disk and download the software to it.
3. Unpack the program from the archives. Program file has name: DSU_name of corresponding
fixture_time identifier, eg. DSU_ArcPixel_Power_14051551.
2.
Fixture software updating:
1. Determine which of your port is available on your PC and connect it:
- with the DMX input of the fixture if you using the flash cable RS232/DMX
- with the USB input of the Robe Universal Interface if you using the USB cable.
Disconnect the fixture from other fixtures in a DMX chain. Turn both the computer and the
fixture on.
2. Switch the fixture to the updating mode:
1.Use the UP] and [DOWN] buttons to find “Special Settings“ menu.
2.Press the [ENTER] button.
3.Use the UP] and [DOWN] buttons to select “ Software Update“ item.
4.Press the [ENTER] button
5.Use the UP] and [DOWN] buttons to select “ Yes“ option
6.Press the [ENTER] button
Note: If you do not want to continue in the software update, you have to switch off and on
the fixture to escape from this menu.
3. We recommend to cancel all running programs before start of the Software Uploader.
4. Run the Software Uploader program. Select desired COM or Robe Universal Interface and then
click on the Connect button.
If the connection is OK, click on the Start Uploading button to start uploading. It will take several
minutes
to perform software update. If the option "Incremental Update" is not checked, all processors will be
updated (including processors with the same software version).
If you wish to update only later versions of processors, check the Incremental Update box.
Avoid interrupting the process. The update status is being displayed in the Info Box window.
When the update is finished, the line with the text “The fixture is successfully updated‘ will appear in
this window and the fixture will reset with the new software.
Note 1: In the case of an interruption of the upload process (e.g. power cut), the fixture keeps the updating
mode and you have to repeat the software update again.
Note 2: If the software update involves also update of software for each pixel (LED module), run the item “Up
-
date Dots” in the menu “Dots” (Dots --> Update Dots).