background image

15

7.Control menu

The control panel situated on the top cover of the ArcPixel Power-CE allows fixture addressing and set the 

driver´s behaviour.

Control elements:

 

[ENTER] button- enters menu,confirms adjusted values and leaves menu. 

 ,    [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.

  [ESCAPE] button- leaves  the menu without saving value.  

7.1 DMX Addr (

Fixture addressing

)

Set DMX Address 

- use this menu item to set the DMX start address of the fixture, which is defined as the first 

channel from which the ArcPixel Power-CE will respond to the DMX controller.

 

IP address - 

select this menu item to set desired IP address. IP address is the Internet protocol

 

address.The IP uniquely identifies any node (fixture) on a network. There cannot be 2 fixtures with

 

the same IP address on the network!

  

Default Address. 

This address is derived from fixture´s MAC address and 

 

 

cannot be changed. Confirm the item 

"Set Address" 

to select this address.

  

Custom Address. 

IP address consists of four decimal numbers, each ranging

 

 

from 0 to 255, separated by dots, e.g., 172.16.254.1. Each part represents a group of 8 bits

 

 

(octet) of the address.

 

 

The following items 

"IP Adr 1"

" IP Adr 2", " IP Adr 3", " IP Adr 4"

 allow to set each 

 

 

part (number) of the address. After setting desired IP address, confirm the item

  

"Set Address" 

to save this address.

Network mask -

 select this menu item to set desired network mask. A network mask is a 32-bit mask used to 

divide an IP address into subnets and specify the networks available hosts. 

The following items 

"Net M.1"

"Net.M.2", " Net.M.3", " Net.M.4"

 serve for seting of each part (number) of 

the net mask. 

After setting desired network mask, confirm the item 

"Set Net M." 

to save adjusted values.

7.2 Info (

Fixture information

)

Use this menu to read useful information about the fixture.

Software version 

- select this menu item to read software versions.

  

Dot 10.0/20

 

-

 

Dot version. 

The items show software version of each LED module.

  

MA. In

 

-

 

Driver version. 

The item shows software version of the ArcPixel Pover-CE.

IP Addr

 

 

- this menu item shows the current IP address.

MAC Addr

 - select this menu item to read the MAC address (the MAC address "runs" on display).

Dots

 - select this menu item to read information about connected LED modules (ArcDot, ArcPix)

  New Dots

 - the item shows the number of recently connected LED modules.

  

Unknown Dots

 - t

he item shows the number of LED modules which were not d

etected

  

 by the dot checking procedure ("Search Dots") or are new dots after replacement.

Summary of Contents for ArcPixel Power CE

Page 1: ...Version 1 6...

Page 2: ...l Power CE 6 4 3 Connecting ArcPixes 6 4 4 Connecting ArcDots 9 5 ArcPix Power DMX protocols 11 6 Control menu map 14 7 Control menu 15 7 1 DMX Addr Fixture addressing 15 7 2 Info Fixture information...

Page 3: ...y ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers t...

Page 4: ...don d alimentation du pi tinement ou pincement particuli rement au niveau des fiches des prises et le point o ils sortent de l appareil Confiez toute r paration un personnel qualifi Une r paration est...

Page 5: ...risk of electric shock do not perform any servicing other than that con tained in the operating instructions unless you are qualified to do so 4 1 Connection to the mains The ArcPixel Power CE is equ...

Page 6: ...and the last ArcPix must not exceed 100 metres For larger installation the ArcPixel Power CE should be connected to the Robe Media Server which allows automatic pixel mapping and full control of the A...

Page 7: ...er Set another needed items in the ArcPixel Power CE menu Note Never connect disconnect LED modules when the ArcPixelPower CE is under voltage Every ArcPix line has to be terminated with the terminati...

Page 8: ...300 modules per fixture Every ArcPix line has to be terminated with the termination box ArcPix The Robe Media Server allows to choose two modes of ArcPixes connection Fixed wiring mode and Picture mo...

Page 9: ...h ArcDots line 3 Connect the ArcPixel Power CE to mains 4 Run procedures Search Dots and Sort Dots from the menu Dots 5 Save adjusted values with the option Store Config 6 Disconnect the ArcPixel Powe...

Page 10: ...aining three UARTs can be used for LED outputs only LED output load is the same as in a case of the control by Artnet max 35 LED modules per LED output max 100 modules per ArcPixel Power CE Every ArcD...

Page 11: ...saturation control 0 100 proportional 6 7 0 255 Blue Blue LED saturation control 0 100 proportional 8 0 255 White White LED saturation control 0 100 proportional ArcDot 3 ArcSource Outdoor 4MC Pixel...

Page 12: ...on control 0 100 proportional ArcPix 3 7 0 255 Red Red LED saturation control 0 100 proportional 8 0 255 Green Green LED saturation control 0 100 proportional 9 0 255 Blue Blue LED saturation control...

Page 13: ...trobe Closed proportional proportional step step ArcDotFlash 2 2 0 127 128 191 192 254 255 Light Intensity Intensity 0 100 Synchronic strobe from slow to fast Random strobe Closed proportional proport...

Page 14: ...New Dots Unknown Dots Dots Search Dots Sort Dots Auto Sort Manual Sort Restore Last Fade Time Off 0 1s 25 5s Dots Curve D Curve 0 255 RGBW 4ch Mode On Off Order Mode Order Compact Order Universe Stor...

Page 15: ...e address The following items IP Adr 1 IP Adr 2 IP Adr 3 IP Adr 4 allow to set each part number of the address After setting desired IP address confirm the item Set Address to save this address Networ...

Page 16: ...ress the ENTER again selected item will start to blink fast and you can set desired values using the UP and DOWN button After automatic or manual sorting do not forget to save changes by means of the...

Page 17: ...desired DMX data input Artnet if this input is selected RJ45 all LED outputs 1 4 are active Wired DMX if this input is selected 3 pin XLR only LED outputs 1 3 are active Display Settings this menu al...

Page 18: ...oftware Update item 4 Press the ENTER button 5 Use the UP and DOWN buttons to select Yes option 6 Press the ENTER button Note If you do not want to continue in the software update you have to switch o...

Page 19: ...atch 1 Press the ENTER to enter menu New Dot and use the UP and DOWN to browse items Sel 1 Sel 2 appropriate dot lights in green pictures 1 2 2 Select the dot 2 and press the ENTER to enter menu Miss...

Page 20: ...r dot 1 picture 5 4 Press the ENTER to go back to the menu New Dot and using items Sel 1 Sel 2 you can see incorporated dots picture 6 7 4 5 6 7 5 Select the item Check channel press the ENTER and aft...

Page 21: ...nu New Dot and select dot 9 picture 13 and press the ENTER to enter the menu Miss Dot The Dot 9 starts flashing in green 11 12 13 8 By means of items Sel 1 Sel 2 Sel 3 select the following colour comb...

Page 22: ...e the message Store will appear Select option Yes if you wish to save the dot changes 9 ArcPixel Power Web manager The ArcPixel Power includes built in web interface allowing quick overview of its set...

Page 23: ...23 Tab DOTS Tab SETTINGS Tab TOOLS...

Page 24: ...ArcPix CE or 100 x ArcDot CE ArcSource Outdoor 4MC Pixel CE ArcDotFlash CE Maximum cable length between output of the ArcPixel Power CE and the last connected LED module ArcPix CE 100 m 100 ArcPixes p...

Page 25: ...N 1305 2023 Connection cable 2m P N 1305 2024 Connection cable 4m P N 1006 2330 Active Terminator for ArcDot P N 1006 2331 Passive Terminator for ArcDot P N 1305 1703 Ferrite GTFC 16 8 16 for ArcDot...

Page 26: ...26...

Reviews: