19
8. Incorporation of new dots (after replacing faulty dots)
In case that some faulty dots have been replaced with the new dots, the following error message will appear
after switching the fixture on:
"Ch. 1 Cfg Mismatch" - it means new dots at LED output 1
"Ch. 2 Cfg Mismatch" - it means new dots at LED output 2
"Ch. 3 Cfg Mismatch" - it means new dots at LED output 3
"Ch. 4 Cfg Mismatch" -it means new dots at LED output 4
You have to use the special procedure to incorporate new dots into existing dot lines.
There is an example of this procedure for the following dots connection:
The dots are connected to the ArcPixel Power and the 5 dots have been replaced (dot 1,2, at output 1 and dot
1,2,3 at output 2).
After switching the ArcPixelPower on,the following message will appear "Ch. 1 Cfg Mismatch".
1.Press the [ENTER] to enter menu "New Dot" and use the [UP] and [DOWN ] to browse items Sel 1, Sel 2
(appropriate dot lights in green) - pictures (1),(2).
2. Select the dot 2 and press the
[ENTER] to enter menu "Miss Dot".The Dot 2 starts flashing in green and by
means of items Sel 1, Sel 2 select the following colour combination of dots when the blue dot will be after the
dot 2-picture (3). The situation on picture 4 is not correct, the blue dot is not closely to green dot.
1 2 3
Note: The replaced dot flashes in green and the dot before this dot (near to the ArcPi
-
xelPower) has to be in red and the dot after the flashing dot has to be in blue. The red
and blue dots have to be closely to the green dot (not second or the third.dot). At least
one position of colour dot (red or blue) has to be always kept.
In case of dot 2 on picture (3) you can select only variant with the blue dot after the
green dot becase the dot 1 has not been incorporated to the dot line yet and cannot
shine in red colour.