CNC Motion Setup/Testing Utility
P/N 70000510B
28
All rights reserved. Subject to change without notice.
31-January-05
BackUp Amp Parameters
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
This reads all parameters from the amplifier and creates a backup file
named DIGAMP-*.BK, where ‘*’ is the selected axis name (i.e. X, Y, Z).
Restore BackUp Amp Parameters
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
This sends the parameters in the backup file to the amplifier.
Restore Default Amp Parameters
This test is only for systems equipped with an ANILAM AC Amplifier (P/N
33001279).
This loads the amplifier with the factory default parameters.
Backup File
The backup file is compatible with the file generated by MotionMaestro.
When functions pertaining to ANILAM AC Drive are selected, the user
needs to have a RS-232 communication cable connected between the
amplifier and the CNC Control.
Exiting the MST Screen (F10)
Press
Exit
(
F10
) to exit the MST Screen and return to the software
selection screen in the Setup Utility.