![Anilam 5000M CNC Manual Download Page 26](http://html1.mh-extra.com/html/anilam/5000m-cnc/5000m-cnc_manual_2943806026.webp)
CNC Motion Setup/Testing Utility
P/N 70000510B
All rights reserved. Subject to change without notice.
23
31-January-05
Saving Final Values
Figure 11, Tuning Parameters Test Results Screen
To save the Tuning Test values:
1. Refer to
Figure 11
. After the Tuning Test, the results are displayed in
the Graphics Area of the screen. Press
TUNING
(
F8
) and highlight
Save Results
.
2. A pop-up is displayed with the following options:
[No Motion]
,
[Feed]
,
[Rapid]
,
[ALL Tables]
. Highlight the table to which you wish
to save the final values, and press
ENTER
. This overrides the values
in the Setup Utility. Normally, choose
All Tables
.
3. The CNC stores the new values in the configuration file.
4. Or, press
F9
to cancel.
NOTE:
ANILAM recommends that you back up your configuration file
before you save tuning results. This will enable the filter
parameters to be recovered if necessary. Refer to
5000M CNC
Setup Utility Manual
, P/N 70000509, for details on backing-up
and restoring setup parameters.
Misc