CNC Motion Setup/Testing Utility
P/N 70000510B
24
All rights reserved. Subject to change without notice.
31-January-05
Miscellaneous Tests (F9)
Press
Misc
(
F9
) to display a pop-up menu with eight (8) selections. The
tests marked
**
on the right apply only for systems equipped with an
ANILAM AC Amplifier (P/N 33001279). The pop-up does not display the
**
notation.
CanBus Test
Rigid Tapping Test
Save Amp Value(s)
**
Amp Test Link
**
Reset Amplifier
**
BackUp Amp Parameters
**
Restore BackUp Amp Parameters
**
Restore Default Amp Parameters
**
CanBus Test
Refer to
Figure 12
. Press
Misc
(
F9
) to display the Miscellaneous Test
pop-up window. Select CanBus Test to display the graphics area and to
troubleshoot the status of all inputs and outputs for the nodes.
CanTest
Line 2
Line 3
Line 1
Line 4
Line 5
Touch : 0
Figure 12, CanBus Test Screen
Table 8
lists the CanBus test results displays.
Table 8, CanBus Test Results Displays
Display
Can Bus Status
Normal
Normal operation
Calibrate
Node found and CNC is calibrating.
Warning
CNC lost a node and is actively searching for active
nodes.
Bus off
Fatal error. The bus has turned itself off due to errors.
U+
Misc