5 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used
Important
On completion of the operation make sure
that there are no malfunctions.
Important
The appliance is supplied at an operating
voltage 400V/3N (indicated on the sticker
applied to the dataplate); conversion
to 230V/3 can be carried out as de-
scribed below.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
1 - Undo the screws
(B)
and remove the control
panel
(C)
.
2 - Modify the connections to the heating element
terminals
(D)
as shown in the electrical system
diagram at the back of the manual.
3 - Fit the jumper
(E)
to make the electrical con-
nection of the terminals
(F)
.
4 - Replace the control panel
(C)
on completion of
the operation.
5 - Remove the test voltage indicator sticker from
the dataplate and apply the new one to identify
the voltage being used