IT
GB
DE
FR
ES
- 20 -
C
139
616
102
.fm
English
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400 V/3 N, which can be switched to 230 V/
3 (see next point).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Undo the screws
(C)
and remove the control
panel
(D)
.
3 - Connect the circuit-breaker
(A)
to the terminal
board
(E)
of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual. Use a flexible cable with at
least type H07RN-F characteristics, rated for an
operating temperature of at least 80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
4 - Replace the control panel
(D)
on completion of
the operation.
ELECTRICAL CONNECTION (090FTE-190FTE)
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400 V/3 N, which can be switched to 230 V/
3 (see next point).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
ELECTRICAL CONNECTION (091FTE-191FTE)
IDM-39616101500.tif
D
C
A
C
E