APPENDICES
88
SERVICE PROCEDURE
D24-IV
Control Board Replacement
Control board replacement
Step 1: Disconnect Power
Depress
plastic
tabs
Slots in
control panel
Unhook tabs
from control
panel slots
To remove lower sensor
Remove clip, pull sensor out.
Step 2: Unplug wire connections from board.
Pull out sensor
Remove clip
Wire connections
DANGER
120 volt exposure. To avoid personal injury,
unplug while performing this procedure.
Page 34
23
25
24
26
Step 3: To remove board, tilt control panel to the right
and slide control hook tabs from slots in control panel.
IMPORTANT
When replacing lower sensor, make sure
sensor is fully inserted into the well and
securely held by the clip on the well groove.
(see photo 25)
Summary of Contents for 24/39
Page 11: ...11 INSTALLATION SECTION 3 Standard Range Hi FloRange Fig3a Fig3b ...
Page 19: ...19 INSTALLATION SECTION 3 Fig 6A Fig 7 ...
Page 23: ...23 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 9 Fig 10 ...
Page 26: ...26 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 13 Fig 14 ...
Page 29: ...29 INSTALLATION SECTION 3 WATER CONNECTIONS Fig 17 Fig 18 ...
Page 52: ...52 PARTS LIST AND ILLUSTRATIONS SECTION 9 Hi Flo Models 62 341 and 54 418 440 ...
Page 93: ...93 Notes ...
Page 94: ...94 Notes ...
Page 95: ...95 Notes ...