AMD5x Passive Infeed Unit and AMD5x Servo Drive - User Guide
ANCA MOTION
D-000129 Rev 09
36
Design of the cabinet should reference the mechanical drawings in
Mounting
4.3.2
The AMD5x must be installed vertically (see
Both the drives and PIU are intended to be mounted in electrical cabinets and it is the
responsibility of the installer to ensure the drives are earthed through the provided protected
earth points denoted with the
symbol.
The AMD5x series drives should be mounted on a zinc plated steel or Aluminium panel.
Painted panels are not to be used.
If any AMD5x 35A (125mm wide) drives are to be installed, these must be mounted adjacent to
the PIU. All 24 Vdc ribbon cable configurations require this installation method. Refer
If any AMD5x Capacitor Modules are to be installed, these must be mounted furthest away
from the PIU, after all Drives. The 24 Vdc ribbon cable does not pass through the Capacitor
Modules.
Warning:
During operation, the AMD5x Regenerative Brake Resistor and heat sink mounting surfaces can reach
above +90°C depending on load. Care must be taken to avoid burns or injury.
Ensure that the gear tray mounting surface is free from all combustible materials and vapours.