Technical Data
ANCA Motion
D-000129 Rev 09
117
10
Attribute
Qualification
Duct Mount Cooling
10.5.4
AMD5x Product Variant
15kW
PIU
24kW
PIU
3A
Drive
6A
Drive
12A
Drive
20A
Drive
35A
Drive
35AH
Drive
Heat-sink losses to duct at
full rated continuous current
60 W
75 W
42 W
70 W
131 W
194 W
298 W
297 W
Losses to cabinet at full
rated continuous current
16 W
18 W
11 W
14 W
21 W
28 W
37 W
37 W
Wall and Recessed Cooling
10.5.5
AMD5x Product Variant
15kW
PIU
24kW
PIU
3A
Drive
6A
Drive
12A
Drive
20A
Drive
35A
Drive
35AH
Drive
Losses to cabinet at full
rated continuous current*
82 W
100 W
59 W
90 W
158 W
235 W
354 W
353 W
Number of fans
1
1
1
1
1
2
3
3
Fan variable speed control
and locked rotor monitor
Yes
*These loss figures include fan losses.