Battery Removal and Replacement
22
Battery Replacement & Firmware Upgrade - 5.2” Modero ViewPoint Touch Panels
4.
Carefully remove the back cover and detach the battery lead at the battery connector (FIG. 6). This will
allow the back cover to be detached from the device.
Installing the New Battery
1.
On the back cover, make sure that the battery connector wiring runs to the right. Make sure that the excess
battery wiring fits in the space to the bottom left of the battery placement (FIG. 7).
2.
Make sure to seat fully the battery plug to the connector in the device (FIG. 6). If fingers cannot be used,
use a clean, nonconductive stick or probe to seat the plug in the connector.
3.
Reattach the back cover, engaging the hook on the lower left of the case (near the speaker) and using it to
swing the back down into place.
FIG. 6
Interior of MVP-5100, including female battery connector
Battery Connector
Attach the residual voltage discharge adaptor (
SAA5966-27-A
) to the old battery and
allow any remaining charge to dissipate. Note that the adaptor may remain warm to
the touch for up to 12 hours.
FIG. 7
Path of excess battery wiring
MVP-BP-5X battery placement
Resistor location
Excess battery
wiring path
Special care must be taken to seat the battery plug so that it does not damage or rub
against the two resistors near the battery connector. When connecting the battery, do
not allow the battery plug to rub against the circuit board.
Summary of Contents for Modero Viewpoint MVP-5200i