10.  GENERAL SAFETY INFORMATION

-13-

SCALDING  HAZARD.    If  the  water 
temperature  is  over  120°F,  household 

members  can  suffer  serious  or  fatal  scalding  and  painful  and 
permanent injury. • The Consumer  Products Safety Commission 
recommends  an  initial  setting  of  120°F,  but  notes  a  slower 
response  time  of  infants,  aged,  disabled  and  other  persons 
increases  the  scalding  hazard  and  may  require  lower  settings.  • 
Always check the water temperature before use, including washing, 
bathing or showering. • Temperature limiting valves are available 
from your plumbing supplier. A check valve must be installed in the 
boiler return line to prevent gravity flow through the heat exchanger. 
This can cause overheating and result in serious or fatal scalding.

SCALDING HAZARD.  If the thermostat is 
not working properly or if this product is not 

installed  in  accordance  with  the  manual,  water  temperature  can 
reach  excessive  levels  that  may  cause  serious  or  fatal  scalding. 
After  installation  and  any  servicing  of  the  unit,  verify  that  the 
thermostat is working and firmly inserted in the thermostat well by 
following the thermostat testing instructions in the manual.

Failure  to  use  the  correct  replacement 
parts may make your product unsafe. 

CALIFORNIA 

PROPOSITION 

65 

WARNING!  WARNING:  This  product 

contains  a  chemical  known  by  the  State  of  California  to  cause 
cancer  and  birth  defects  or  other  reproductive  harm.  (California 
Installer/Contractor  -  California  law  requires  that  this  notice  be 
given to consumer/end user of this product.) 

For more information: 

www.amtrol.com/prop65

In  limited  circumstances,  space  heating 
can be lost in the home with unit utilizing 

priority mode.  Any demand for space heating is postponed until 
the Boiler Mate

®

 has reached its set temperature.  This delay in 

supplying the space heating zones is usually not noticed by the 
inhabitants of the living spaces.  However, in the event of certain 
malfunctions  such  as  circulator  or  thermostat  failure,  space 
heating  could  be  delayed  indefinitely.    If  undetected  and 
uncorrected, freezing damage to piping could result.

If a steel hydropneumatic tank is in place, 
AMTROL

®

 recommends replacing it with 

a properly sized EXTROL

®

 expansion tank. Otherwise, significant 

heat transfer problems can occur by causing air to be trapped in 
the  heat  exchanger.  If  the  boiler  system  has  an  EXTROL

®

  or 

Radiant EXTROL

®

 expansion tank and the boiler temperatures are 

being  changed,  resize  the  EXTROL

®

  or  Radiant  EXTROL

®

 

expansion tank.

If installing on city water supply a properly 
sized  THERM-X-TROL

®

  is  required  with 

the  BoilerMate

® 

  and  should  be  installed  as  set  fo rth  in  the 

THERM-X-TROL

®

 product installation manual. Contact your water 

supplier or local plumbing inspector for additional information.

Prevent  pressure  build-up  in  any  existing 
internal tankless coil.  Do not plug incoming 

or outgoing tappings in the internal tankless coil plate.  Leave the 
coil in the boiler and leave system connections open, to prevent 
pressure build-up.

Electrocution  Hazard.    The  BoilerMate

®

 

must  be  electrically  grounded.  Electrical 

supply  must  come  from  the  boiler  side  of  boiler’s  emergency 
shut-off switch in order to prevent unsafe operation.

Chlorine  Aggressive  Water:  The  water 
quality  can  significantly  influence  the  life 

of  this  Product.    You  should  test  for  corrosive  elements,  acidity, 
total solids and other relevant contaminants, including chlorine and 
treat  your  water  appropriately  to  insure  satisfactory  performance 
and prevent premature failure. 

Note:    Inspect  for  shipping  damage  and  notify  freight  carrier  or 
store where purchased immediately if damage present.  To avoid 
risk of personal injury and property damage, if the product appears 
to be malfunctioning or shows signs of corrosion, call a qualified 
professional immediately.  Current copies of the Product manual 
can be viewed at www.amtrol.com.  Use proper safety equipment 
when installing.

EXPLOSION  HAZARD.    The  pressure  of 
the heat transfer medium must be limited to 

a maximum of 30 psig by an approved safety or relief valve on your 
boiler.    The  BoilerMate

®

  pressure  must  be  limited  to  150  psig 

maximum by the installation of a temperature and pressure relief 
valve  (included).  The  relief  tube  must  be  plumbed  to  a  suitable 
drain per code. No reducing coupling or other restriction may be 
placed in this line.

This  Product,  like  most  Products  under 
pressure, may over time corrode, weaken 

and  burst  or  explode,  causing  serious  or  fatal  injury,  leaking  or 
flooding  and/or  property  damage.    To  minimize  risk,  a  licensed 
professional must install and periodically inspect and service the 
Product.    A  drip  pan  connected  to  an  adequate  drain  must  be 
installed if leaking or flooding could cause property damage.  Do 
not locate in an area where leaking could cause property damage.

EXPLOSION OR RUPTURE HAZARD. A 
relief  valve  must  be  installed  to  prevent 

pressure in excess of local code requirement or maximum working 
pressure designated in the Product Manual, whichever is less.  Do 
not  expose  Product  to  freezing  temperatures  or  temperatures  in 
excess of the maximum rated operating temperature.

If not installed by the boiler manufacturer, 
install  a  low  water  cut-off  or  pressure 

reducing valve on your boiler so that leaking will not result in a dry 
boiler which if the boiler continues to fire, will cause an explosion 
hazard.

This  unit  must  be  installed  as  a  separate 
heating zone.  Do not connect this unit to 

an existing heating zone or dangerous over-heating will result.

Do not drain this appliance before shutting 
off the supply valve and opening the relief 

valve or another downstream fixture, as it will damage this unit.  A 
vacuum breaker should be installed to avoid damaging the liner. 
Damage to the unit and leakage can occur if a vacuum breaker is 
not installed.

USE 

GLYCOL 

ONLY 

WITH 

DOUBLE-WALLED  HEAT  EXCHANGER 

MODELS.    Avoid  risk  of  ingesting  a  toxic  glycol  fluid.  The  heat 
transfer medium should be water. If glycol must be used, it should 
only  be  used  with  double-walled  heat  exchangers  and  closely 
moitored for leakage.

Summary of Contents for Champion CH-41BZ

Page 1: ...URRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE AS APPLICABLE THIS IS THE SAFETY ALERT SYMBOL IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class...

Page 2: ...seepage or leakage of glycol to surfaces where humans or animals can ingest it use glycol only in double walled units so that any leaks will most likely be released to the atmosphere However a leak to a surface area may still occur so any use of glycol must be monitored closely and humans and animals should be protected from contact with the unit Do not connect the BoilerMate domestic supply with ...

Page 3: ...iler system has an EXTROL or Radiant EXTROL expansion tank and the boiler temperatures are being changed resize the EXTROL or Radiant EXTROL expansion tank 20 15 10 5 0 0 2 4 Flow GPM Pressure Drop ft 6 8 MODEL OPTION CIRCULATOR ZONE VALVE SHUTOFF VALVE VACUUM BREAKER RELIEF VALVE THERMAL EXPASION TANK DRAIN CH 41 CH 41 CH 80 Z BZ Z 4GPM If Circulator not used 3 4 Full Port or 1 STD 4 1 Included R...

Page 4: ...e T P relief valve and the tank Note Valves for reducing point of use temperature by mixing cold and hot water are available Consult a licensed plumber or the local plumbing authority BOILER PIPING 1 Plumb the circulator or zone valve onto the BOILER SUPPLY fitting 2 Pipe the BOILER RETURN connection to the boiler return fitting Be sure the return line is NOT plumbed to the suction side of any hea...

Page 5: ... 5 PIPING USING DEDICATED CIRCULATOR PUMP RECOMMENDED PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR ...

Page 6: ...ch as one having a back flow preventer in the cold water supply line means shall be provided to control thermal expansion Contact the water supplier or local plumbing inspector on how to control this situation BOILER PIPING 1 Plumb the circulator or zone valve on the BOILER SUPPLY line If using a separate circulator the pump flange can be mounted directly to the threaded pipe marked BOILER SUPPLY ...

Page 7: ... 7 CH 41BZ PIPING USING SEPARATE CIRCULATOR PUMP RECOMMENDED PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR ...

Page 8: ...conduit metal clad cable or raceways Power Limited Circuit Cable need not be provided with the protection specified above if it is securely fastened to the appliance jacket and follows the contour of the appliance jacket Thermoelectric circuit wiring shall be exempt from this provision Note Strain relief shall be provided for all conductors leaving an enclosure For low voltage wiring strain relief...

Page 9: ... Zone Relay BoilerMate Circulator BoilerMate Thermostat 1 BoilerMate THERMOSTAT 2 3 BLACK L1 HOT L2 WHITE ON BOILER CONTROL FROM BOILER CONTROL A 24 VOLT T T T T ON BOILER CONTROL END SWITCH BoilerMate THERMOSTAT FROM BOILER CONTROL BLACK L1 HOT L2 WHITE MOTOR B 24 VOLT ZONE VALVES SCHEMATIC 3 ...

Page 10: ...dered normal and will clear as hot water is used 3 START HEATER Turn power on to the unit Dial should have the knob rotated to the 120 F mark for safety The circulator and boiler should start momentarily If not check wiring and consult the troubleshooting section in this manual 4 CHECK OPERATION The BoilerMate will begin to heat Depending upon the size of the BoilerMate output of the boiler and th...

Page 11: ...heck valve stuck open 1 Reduce temperature setpoint 2 If Boiler Return is plumbed to the suction side of a heating circulator overheating will occur when the home s heat is on Fix plumbing 3 Fully insert temperature sensor bulb 4 Repair or replace 5 Clean repair or replace Noise from BoilerMate 1 Air in boiler loop 2 Faulty circulator pump 3 Thermal expansion 4 Normal noise during initial fill 1 P...

Page 12: ...TS Number Description Part Number 1 Heat Exchanger w Gasket CH41Z 2703R003 2 Hot Water Outlet Tee 9403R123 3 Dip Tube CH 41Z only 2703R001 Dip Tube CH 80Z only 2702R001 4 Bottom Drain 9340R160 5 Dial Aquastat 2704 093 6 Safety Relief Valve 2700R116 7 Top Cap Assembly CH 41Z CH 80Z 2704R007 8 CH 41BZ Coil 2708R003 9 CH 80Z Coil 2702R002 5 7 6 2 1 3 Not shown ...

Page 13: ...and leave system connections open to prevent pressure build up Electrocution Hazard The BoilerMate must be electrically grounded Electrical supply must come from the boiler side of boiler s emergency shut off switch in order to prevent unsafe operation Chlorine Aggressive Water The water quality can significantly influence the life of this Product You should test for corrosive elements acidity tot...