3. REQUIRED COMPONENTS AND
ACCESSORIES CHECKLIST
Heat Exchanger Pressure Drop
Use this chart to select the proper circulator for your BoilerMate
®
.
If a steel hydropneumatic tank is in place, AMTROL
®
recommends replacing it with a
properly sized EXTROL
®
or Radiant EXTROL
®
expansion tank. Otherwise, significant
heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has
an EXTROL
®
or Radiant EXTROL
®
expansion tank and the boiler temperatures are being changed, resize the
EXTROL
®
or Radiant EXTROL
®
expansion tank.
20
15
10
5
0
0
2
4
Flow (GPM)
Pr
essur
e Dr
op (ft)
6
8
MODEL OPTION CIRCULATOR
ZONE VALVE*
SHUTOFF
VALVE
VACUUM
BREAKER
RELIEF
VALVE
THERMAL
EXPASION TANK
DRAIN
CH-41
CH-41
CH-80
Z
BZ
Z
4GPM
*If Circulator not used
3/4” Full Port or 1”
STD
4
1
Included
Required (See
Therm-X-Trol®
Sizing Guide)
Included
ALL INSTALLATIONS REQUIRE TEFLON
®
SEALING TAPE OR PIPE DOPE FOR THREADED JOINTS.
SEE HEAT EXCHANGER PRESSURE DROP CHART TO DETERMINE PUMP HEAD REQUIREMENTS.