SafeWizard
Operating Instructions
American Security Products Company
Last Revision 10/17/2008
Page 68 of 73
Document 4305199
Procedure for field upgrade.
1. Press the “Help” button on the Controller key pad display and check if the version is at least 3.04.
If not, “flash” the latest software into the Controller using a “serial” cable with male / female ends and
the “WizDat” program v2.00. See “Flash Update w/
WizDAT
application procedure contained on the
SafeWizard Upgrade CD, part number .
Note: Check for the latest version of Controller code with the factory.
2. Turn off the power and replace the current “Power Supply” top with the N.M.P.S. supplied.
Be sure the flat grey data cable is securely plugged into one of the 6-cond. ports on the end where
the label reads VaultLAN Power / VaultLAN Active on the cover.
Plug the A/C power transformer plug into the opposite end where the label reads Battery on the
cover.
3. Plug the Cat 5 Ethernet cable into the Network port at the location where the label reads Network on
the cover.
4. Power up the system and at the “LOCKED” screen, sign in with the “Factory” key or code provided by
the factory. There will be a message that states “Factory code does not match N.M.P.S. Enter proper
factory code and press “ENTER”. This code will be provided by AMSEC. After pressing “ENTER”, the
display will show the message “Writing To Memory”. This can take several minutes depending upon
the amount of information in the system.
5. At the Main Menu, select 3- Administration, 1- Set Up Users, 1- Add A New User.
Select “0- None” for Validation Mode. At this time, note the User 2 digit position number. This two digit
number is used with a 6 digit number to sign into the SafeWizard lock system. Now enter the name,
REMOTE ADMIN, and press ENTER. Then select 1- Selecting A Profile. At the next screen, press
“NEXT” until #13- Remote Administrator is reached. Press QUIT / SAVE.
Sign into the system using the first two digits of the REMOTE ADMIN followed by 1, 1, 1, 1, 1, 1 and
press ENTER. The screen will display a message that the temporary PI.N. has expired, enter a new 6
digit number. The number can not be a sequential or repeating number. Enter the same 6 digit
number a second time. At the “MAIN” menu, proceed to step #6.
6. At the “MAIN” menu select 3-Administration, 4-Set Up Factory, 3-Configure Devices, 6-Network, 1-
Settings.
Select “YES” for Enable. Press ENTER.
Note: Consult with your I.T. department for help setting up the “Listening Port” and IP Address
information. After that information has been established, press “QUIT / SAVE”.
7. At the Network / Modem P/S screen select 2-Copy Audits to NMPS.
This can take several minutes to complete and then the screen will change back to the Device
Configuration screen.
8. Now select 6-Network and 3-Copy Users to NMPS. After this step is completed, the screen will revert
back the Device Configuration screen.
Press “MENU” then “Quit / Save” to return to the “LOCKED” screen.
9. Switch the power “Off” - then “On” to synchronize the N.M.P.S. with the Controller.
10. On your computer, open
WizSetUp
and create a new information screen for connecting remotely by
selecting “Tools”, then “Options”.
11. In the “Connection Method” box, select “Network” if not already selected, then select “Add” to open a
blank window.