Then turn down safeguard or press
(when no hood) to start t h e spin, comes Fig. 22 means the
wheel is balanced.
Fig. 22
5.
Self-calibration
5.1.
Self-calibration of wheel balancer
Turn on the balancer, install a medium-size wheel (13″-15″)which can use clip-on weight, set “a b d” value, then
Do the self-calibration whenever you think the balancer is not accurate. The 100g weight must be accurate.
Step 1
Press
and hold, then press
comes
Step 2
Put down safeguard or press
(when no
hood) to start the spin, after spin stop
comes
Step 3
Open the safeguard and clip a 100-gram weight
on the outside 12 o’clock position, put down safe
guard or press
(when no hood) to start
spin, after spin stop
comes
Step 4
Open the safeguard and clip a 100-gram weight on
the inside 12 o’clock position, put down safeguard
or press
(when no hood) to start the spin,
after spin stop
comes
self-calibration finished