SECTION B - 601ES EXPLOSIVE SAFETY DMM
IGNITER TESTER - SPECIFICATIONS *
Warm-up Time 5 Minutes
20.0 V
2.0 V
(for 1 year @25°C ± 10°C)
Operating
0°C to 50°C
Storage
-20°C to 70°C
0.0 % per °C (from 0°C-15 C and 35°C-50°C)
. . (20,000 count) 4½ digit Liquid Crystal Display (
) with high contrast backlight
. . . . LCD Displays "
" (front panel enunciated)
. . . ( open circuit or select next higher range) Displays "
"
. . . . . Approximately 300 ms
(Indication range 0 to 10 mA Fullscale) - Accuracy ± 3.0%
. . . . . . . . double diode clamped at <1.6 volts
. .
Batteries (4 each "AA") can be
high capacity re-chargeable 1.2 V - NiMH (i.e. Energizer 2500 mAHr
)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.5" (24cm) W x 11" (27cm) D x 3"(8cm) H
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 lbs net; 15 lbs shipping
True RMS AC-DC Voltage Measurement - DC and 60 Hz
True RMS AC-DC Current Measurement - DC and 60Hz
Signal Source:
50 mV
5 mA
200 V DC or AC RMS range . . . . . . . . Accuracy ± 0.50% of range
DC or AC RMS range . . . . . . . . Accuracy ± 0.50% of range
DC or AC RMS range . . . . . . . . Accuracy ± 0.50% of range
2.0 Amperes DC or AC RMS range . . . . . . . . Accuracy ± 0.50% of range
2.0 Ohm Range thru 20 KOhm ranges . . . . . . . . . . . . . . ±0.05% of reading ± 0.05% of range
2 Wire”
± 0
(50 mV and 5 mA - 20,000 count display)
Voltage mode display accuracy: 50 mV 50 counts on the 2.0 Volt range
Current mode display accuracy: 5 mA 10 counts on the 2.0 ampere range
±
05
°
. . .
heavy duty Alkaline (1.5V Duracell Coppertop Ultra or
equivalent) or
or equivalent
Table B-1 Specifications
Resistance Measurement Accuracy:
Temperature Range
Temperature Coefficient for all functions
Instrument Display
LCD
Low Battery Indication
LO BAT
Over-Range Indication
>>>OR
Measurement Update Rate
Analog DC Milliammeter
Open Circuit Current Source Compliance Voltage
Power
Dimensions
Weight
4 Wire Mode
“
resistance mode : ( if shorted leads can be “zero’ed” ) - additional
0. 5% of range
+
+
*
revised 14JAN2006
600 V DC or AC RMS range . . . . . . . . Accuracy ± 1.0% of range
7