3
Introduction
The 34XR-A is a True rms autoranging handheld digital multimeter for measuring
or testing the following:
•
DC and AC voltage
•
Temperature
•
DC and AC current
•
Capacitance
•
Resistance
•
Diodes
•
Frequency
•
Continuity
•
Dutycycle
Additional features include: MIN MAX, HOLD, Backlight, and Range Lock
Making Measurements
Verify Instrument Operation
Before attempting to make a measurement, verify that the instrument is operational
and the battery is good. If the instrument is not operational, have it repaired before
attempting to make a measurement.
Range Selection
In addition to autoranging the 34XR-A allows you to manually select and lock a
range by pressing the
RANGE
button.
RANGE
appears on the display to indicate
that manual ranging is active. Each subsequent press of the range button steps the
meter to the next higher range. When the highest range is reached the next press
returns the meter to the lowest range. To return to autoranging press and hold the
RANGE
button for 2 seconds.
RANGE
no longer shows on the display.
Use autorange for all initial measurements. Then, when appropriate, use the
RANGE
button to select and lock a range.
Warning
To avoid electrical shock while manual ranging use the display
annunciators to identify the actual range selected.
Correcting an Overload (
o
or -
o
) Indication
W
An
o
indication may appear on the display to indicate that an overload condition
exists. For voltage and current measurements, an overload should be immediately
corrected by selecting a higher range. If the highest range setting does not
eliminate the overload, interrupt the measurement until the problem is identified
and eliminated. The
o
indication is normal for some functions; for example,
resistance, continuity, and diode test.
Measuring DC Voltage
See Figure
-1-
1.
Set the Function Switch to
v
.
2.
If
RANGE
is displayed, press the
RANGE
button to enable autoranging.
3.
Connect the Test Leads: Red to
E
, Black to
COM
4.
Connect the Test Probes to the circuit test points.
5.
Read the display, and, if necessary, correct any overload (
o
) conditions.
Summary of Contents for IR608A
Page 65: ...13 Figure 1 DC Voltage and AC Voltage functions ...
Page 66: ...14 Figure 2 ACA DCA Current clamp on function ...
Page 68: ...16 ...
Page 81: ...29 Figure 1 Fonctions de tension alternative et de tension continue ...
Page 82: ...30 Figure 2 Fonction de la pince de courant A c a et A c c ...
Page 84: ...32 ...
Page 97: ...45 Abbildung 1 Spannungsfunktionen DC und AC ...
Page 98: ...46 Abbildung 2 Stromzangenfunktionen ACA und DCA ...
Page 100: ...48 ...
Page 113: ...61 Figura 1 Funzioni di tensione in c c e c a ...
Page 114: ...62 Figura 2 Misure di c a e c c mediante la pinza amperometrica ...
Page 116: ...64 ...
Page 129: ...77 Figura 1 Funciones de voltaje CC y CA ...
Page 130: ...78 Figura 2 Función de corriente ACA y ACC con la pinza ...
Page 132: ...80 ...
Page 145: ...93 Figur 1 Funktioner för likspänning och växelspänning ...
Page 146: ...94 Figur 2 Klämfunktion för ACA och DCA ström ...
Page 147: ...95 Figur 3 Funktioner för motstånd kontinuitet kapacitans och diod Figur 4 Byte av batteri ...
Page 148: ...96 ...
Page 150: ......
Page 151: ... MADE IN TAIWAN PATENTS PENDING www amprobe com 5 6 3 4 1 2 34XR A 34XR A ...
Page 153: ......
Page 165: ...12 4 3 2 1 5 4 3 2 1 5 1 2 V V 34XR A 34XR A ...
Page 167: ...14 2 1 8 3 4 5 4 7 5 6 4 7 5 6 A 3 A 2 1 8 34XR A 34XR A ...
Page 168: ...15 3 4 6 5 2 1 5 3 4 6 6 7 2 1 7 34XR A 34XR A ...
Page 169: ...16 6 2 8 1 3 5 4 1 7 4 5 6 2 9 3 34XR A 34XR A ...
Page 170: ...17 4 11 1 3 2 2 4 K 3 1 5 10 34XR A 34XR A ...
Page 171: ...18 3 2 1 4 12 2 4 2 13 34XR A ...
Page 183: ...12 ...
Page 195: ...12 ...
Page 207: ...12 ...
Page 219: ...12 ...
Page 220: ...C M Y CM MY CY CMY K ...