HTRS230V(30) THERMOSTAT - FULL USER MANUAL

Summary of Contents for HTRS230V(30)

Page 1: ...HTRS230V 30 THERMOSTAT FULL USER MANUAL ...

Page 2: ......

Page 3: ...II A work with RM 16A relay module heating source control 14 III B work with RM 16A relay module connection to a solid fuel boiler controller 14 III C work with RM 16A relay module connecting an electrical device with a higher power 15 3 Before you start first power up 16 3 1 LCD icon description 16 3 2 Button description 16 3 3 First power up sequence 17 4 Work modes 18 5 User settings basic sett...

Page 4: ...ations in accordance with standards and regulations in force in the given country and in the EU Never try to connect the device other than as described in the manual Before assembly repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live The device may not be exposed to extr...

Page 5: ...signed heating system for example the temperature of the heating medium Likewise reducing the temperature even more while cooling the room will not result in faster cooling By setting the thermostat to a lower setpoint the room will be controlled at a lower temperature and will save energy The best way to find the temperature that is right for you is to set the room thermostat to a low temperature...

Page 6: ...n case if any of listed dangers occur you have to use additional protection measures anti dust and explosive gases tight cover or prevent their formation Furthermore thermostat can t be used in condensation of water vapor conditions and be exposed to water action 1 2 3 2 3Wall mounting Mounting to mount thermostat you can use accesories included with the set mounting screws Remove back cover to mo...

Page 7: ...ure reduction 230V output SL 230V AC input signal CO Switching jumper between heating and cooling input 230V AC 2 4 Connection description HTRS 230 L N CO L AC 230V N T30NC HTRS Wejście NSB NSB input Legend Thermal actuator Symbols explanation ...

Page 8: ...rksmainlyasaSLAVEthermostat groupthermostat whichmeansthatitcanbecontrolledbyaMASTERthermostate g HTRP230V 50 MASTER thermostat controls SLAVE thermostat only when SLAVE thermostat is in AUTO mode Comfort SUN and economy MOON setpoint temperatures are set individually on each thermostat but switching between those temperature is based on time schedule taken from HTRP230 50 thermostat which works l...

Page 9: ...Pump Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions L AC230V L N N 1 8 Strefy 1 8 Strefy 1 8 Strefy KL08NSB Pump Boiler Power L N SL T30NC L N SL T30NC L N SL T30NC lu ub VS30 RT200 RT520 L L L L or or L 1 2 BOILER CONNECTION 1 8 Zones 1 8 Zones 1 8 Zones 3 4 N N N N N N L max 6 per zone max 6 per zone max 6 per zone e g HTRP230V 50 HTRS230V...

Page 10: ... THB23030 T30NC230 Power Supply 230V AC Actuators wires 2 x 0 75mm2 Pump control wires 2 x 1mm2 Boiler control wires 2 x 1mm2 KL06 PL07 PL06 PUMP optional BOILER 4 wires x 0 75 mm2 4 wires x 0 75 mm2 SLAVE MASTER e g HTRP230 50 HTRS230 30 e g HTR230 20 ...

Page 11: ...6 M Power L N L N T30NC max 6 na strefę RT10 RT20 Np Np L N 1 6 Strefy PL06 L N L N T30NC max 6 na strefę RT520 COM NO lub NC NO PODŁĄCZENIE KOTŁA L AC 230V L N N 1 6 Strefy KL06 M Power L N L N T30NC max 6 na strefę RT10 RT20 Np Np L N 1 6 Strefy PL06 L N L N T30NC max 6 na strefę RT520 COM NO lub NC NO L N MAX 5 2 A AC 230V lub 24V L AC 230V L N N 1 6 Strefy KL06 M Power L N L N T30NC max 6 na s...

Page 12: ...thermostat doesn t work as a SLAVE group thermostat no effect from potential MASTER thermostat which means that it can be just a simple pump boiler or actuator controller PLEASE NOTE The same operating rules apply to wiring center KL06 THB23030 PUMP optional T30NC230 BOILER 3 wires x 0 75 mm2 Power Supply 230V AC Actuators wires 2 x 0 75mm2 Pump control wires 2 x 1mm2 Boiler control wires 2 x 1mm2...

Page 13: ...Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions L AC230V L N N 1 8 Strefy 1 8 Strefy 1 8 Strefy KL08NSB Pump Boiler Power L N SL T30NC L N SL T30NC L N SL T30NC lu ub VS30 RT200 RT520 L L L L or or L 1 2 BOILER CONNECTION 1 8 Zones 1 8 Zones 1 8 Zones 3 4 N N N N N N L max 6 per zone max 6 per zone max 6 per zone HTRS230V 30 HTRS230V 30 HTRS230V 30 ...

Page 14: ...ltage thermostat to a boiler or other device with an ON OFF contact HTRS230V 30 BOILER CONNECTION input III B work with RM 16A relay module connection to a solid fuel boiler controller PLEASE NOTE Activate the thermostat in the solid fuel boiler controller RM 16A L AC 230V N L AC 230V N NO NO COM COM wejście NC SL L N SL N L PODŁĄCZENIE KOTŁA VS30 Np VS30 Np 091FL Np Podłączenie regulatora napięci...

Page 15: ... Strefy KL08NSB Power L N L N SL MA 16 5 input HTRS230V 30 III C work with RM 16A relay module connecting an electrical device with a higher power than the thermostat relay allows PLEASE NOTE The maximum current consumption of an electrical device shouldn t exceed 16A L N power supply 230V SL 230V AC actuator control signal NO COM NC voltage free output fuse Legend Symbols explanation Pump Valve a...

Page 16: ...otection mode 8 Temperature unit 9 Current set temperature 10 Manual mode override temp 2 1 3 4 5 6 7 9 10 8 OR 1 Increase or decrease setpoint temperature 2 Select installer parameter value 1 Mode selection 2 Moving between parameters 1 OK key Short press to confirm selection 2 Long press to save and exit 3 When Main Screen long press to enter the user settings Hold down these buttons for 3 SECON...

Page 17: ...ill display the software version 3 3 First power up sequence display will show all icons After all the main screen will be displayed To power on the thermostat you have to connect it to the 230V power supply then 2 1 3 4 3 ...

Page 18: ...ined temperature in heating mode or the lowest if thermostat works in the cooling system Acting alone works as a manual mode Temperature range from 5 C to 35 C Economic temperature mode pre defined setpoint temperature Usually set at night or when we are out of the house Acting alone works as a manual mode Temperature range from 5 C to 35 C Automatic mode temperature schedule follows MASTER thermo...

Page 19: ...resensorbyagivennumberofdegrees intherange from 3 0 C to 3 0 C in 0 5 C steps To calibrate thermostat s temperature sensor please follow steps below 1 4 6 5 2 3 Hold button for 3 seconds to enter the menu To increase decrease value use and buttons Go to the thermostat calibration settings using button Confirm by button Confirm by button Thermostat will go back to the main screen after saving the s...

Page 20: ...wer is applied to the CO terminal then thermostat automatically switches to cooling mode Set thermostat for heating using and buttons Confirm by button 2 1 1 2 By external ON OFF switch MANUALLY AUTOMATICALLY 3 3 HTRS 230 L N CO L AC 230V N T30NC HTRS 230 KL08 NSB L N CO L SL N Wejście NSB NSB output The heating cooling mode for the thermostat can be changed manually or automatically via CO termin...

Page 21: ...on Parameter Values Description Default Values d01 Heating Control This parameter defines the algorithm of the room temperature control 0 PWM Pulse width modulation algorithm ensures reduction of overdrive states and economic operation of the system It is an advanced algorithm designed to precisely maintain room temperature 0 1 SPAN 0 25 C 0 5 F 2 SPAN 0 5 C 1 0 F d02 Room temp offset 3 0 C to 3 0...

Page 22: ...ter allows to limit temperature setpoint range by setting maximum setpoint for heating and cooling modes Default temperature setting range 5 C 35 C 35 C d13 Minimum limitation of cooling setpoint 5 C 40 C This parameter allows to limit temperature setpoint range by setting minimum setpoint for heating and cooling modes Default temperature setting range 5 C 40 C 5 C d18 Heat Cool Mode Selection 0 N...

Page 23: ... default settings please follow steps below 1 2 3 4 7 5 6 Wait few moments to finish factory reset procedure thermostat will display the software version after all main screen will appear Thermostat has been succesfully reseted Use or buttons to choose code 47 Press button to confirm Select del and confirm choice by pressing button 3 ...

Page 24: ...5 mm 85 mm Power supply 230VAC 10 50 60 Hz Rating max 0 5 A Temperature setback Adjustable Temperature range 5 C 35 C Span 0 5ºC or 0 25ºC Storage temperature 20 C to 60 C Ambient temperature 0 C up to 45 C Degree of protection IP 30 CE conformity according to Class II EN60730 Housing material PC V2 Color RAL 9010 pure white Control method PWM algorithm Hysteresis 0 5ºC or 0 25ºC Connection Screw ...

Page 25: ...willbefreefromanydefectinmaterialsorworkmanship andshallperforminaccordancewithitsspecification foraperiodoffiveyearsfromthedateofinstallation SALUSControlssoleliabilityforbreachofthiswarrantywillbe atitsoption torepairorreplacethe defective product ...

Page 26: ...OLS Sp z o o Sp k Rolna 4 43 262 Kobielice Poland www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice Ver 6 Issued 21 VII 2020 Soft version 3 0 ...