d07
Valve Protection
0
Enable/Disable.
Valve protection function is intended to protect thermostatic valves against
getting stuck or jamming (e.g. in summer time when heating system is disa-
bled). If thermostat doesn’t send a signal for heating for a period of 7 days, then
heating is turned on for a very short period of time just to move the actuators.
1
1
d08
Frost Setpoint
5°C - 7°C
In Frost protection mode the thermostat is displaying actual room tem-
perature and maintain „frost protection” setpoint temperature specified
in thermostat settings. When thermostat works in Frost protection
mode then you have no possibilities to change temperature setpoint.
5.0°C
d12
Maximum limitation of
heating setpoint
5°C - 35°C
This parameter allows to limit temperature setpoint range by setting
maximum setpoint for heating and cooling modes. Default temperature
setting range: 5⁰C - 35⁰C
35°C
d13
Minimum limitation of
cooling setpoint
5°C - 40°C
This parameter allows to limit temperature setpoint range by setting
minimum setpoint for heating and cooling modes. Default temperature
setting range: 5⁰C - 40⁰C
5°C
d18
Heat/Cool Mode Selection
0
No connection
0
1
Connection
d19*
Cooling Blocked
0
Cooling allowed
0
1
Cooling disabled
d20
Actuators loading selection
for different temperature
compensation.
1
x1 actuator loading
1
2
x2 actuators loading
3
x3 actuators loading
4
x4 actuators loading
5
x5 actuators loading
*Cooling Blocked -
at „1” we block cooling for a single room until the device receives a heating command. During the blocking of the cooling function
no message is displayed.
*Please note!
d19 parameter will be available only if d18 is set on 1 (Heat/Cool Mode selection Connected).