Ampetronic D Series Installation Handbook & User Guide
Page 34
MASTER MODE ENABLED:
This message is seen when the plug is removed from the slave in
socket on the driver .
These messages appear in the status menu when the associated error is present
:
Driver Error Power De-rate:
The driver is overloaded and the drive current has been reduced .
Driver Error Open
The driver has detected an open circuit on loop A .
Circuit CHA:
Driver Error Open
The driver has detected an open circuit on loop B .
Circuit CHB:
Driver Error Heatsink:
The internal heatsink is too hot and the driver current on both
Too Hot:
channels has been reduced .
Driver Error Internal Error:
An unspecified internal error has occurred. Contact Ampetronic
technical support .
Driver Error Chan. A Clipping:
The driver output maximum voltage is being exceeded and the
loop A signal is being clipped .
Driver Error Chan. B Clipping:
The driver output maximum voltage is being exceeded and the
loop B signal is being clipped .
Display Screen not illuminated
• Check that the power switch is toggled to the ON (I) position.
•
Check fuse continuity . A 20mm fuse is incorporated into the AC POWER inlet . It is necessary
to remove the power cord before extracting the fuse holder . Test the continuity of the fuse
using a multimeter . A spare fuse is provided in the fuse holder .
Any replacement fuse MUST be of the same rating and type as printed on the rear of
the unit .
COMPRESSION LEDs not illuminating
Check input connections .
Ensure that the input gain levels (INPUT1 or INPUT2) are set to the appropriate level(s). Check
there is sufficient signal level for the required input.
CURRENT LEDs not illuminating
There are many possible causes for this:
•
Check the COMPRESSION LEDs are illuminating .
•
Check that the CURRENT levels are set appropriately .
• Ensure the ERROR LED is not flashing.
•
Check that the loop cables are connected, terminated correctly and inserted into the LOOP
OUTPUT sockets .
•
Check the loops are not open circuit, short circuit, or connected to earth (see instability or high
frequency noise section of Troubleshooting)
•
Switch the unit off and turn back on .
Note: You can listen to the actual loop signal by using a pair of headphones plugged into the
monitor socket. Channel A = left, channel B = right
Summary of Contents for d series
Page 1: ...D Series Installation Handbook User Guide www ampetronic co...
Page 2: ......
Page 45: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 43...
Page 46: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 44...
Page 47: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 45...
Page 48: ...Contents Copyright Ampetronic Ltd 2016 All rights reserved UP1 9001 4...