Ampetronic D Series Installation Handbook & User Guide
Page 22
driver until the slider handle is released (mouse click up or finger off touchscreen). Alternatively it is
possible to click in the text box next to the slider and enter a value directly . There are two important
points to note about directly entering values into the text box .
First, although the slider will move as the value is altered, no information is sent to the driver as this
happens .
Second, the value only gets sent to the driver when the edited slider “loses focus” which means that
you have to click (or touch if on a mobile device) at a point somewhere away from the slider you
have just adjusted . Only at this point is the new value transferred to the driver .
There are 13 adjustable parameters on the settings page:
Test Signal Freq:
Controls the frequency of the continuous sine wave test signal
Test Signal:
Drop down box that selects the test signal from OFF, Pink Noise,
Sine Wave, Combi 1K, Combi 1 .6K and Combi 2 .5K
Current:
Controls the level of current to loops A and B . Maximum current is
with the slider at 0 dB and minimum with the slider at -80 dB
Current Offset:
Controls the level of current B with reference to current A . A
(Only available on
positive value means that more current is driven through loop B
dual output Drivers)
than loop A whilst a negative value means that less current is
driven through loop A than loop B
Phase Shift:
This is a drop down box with OFF and ON options . ON places a
90 degree phase shift on the current between loops A and B .
MLC:
Metal Loss Compensation (MLC). Corrects system frequency
response due to metal structures in a building . The drop down box
allows the selection of OFF, Custom or a slope of 0 .25dB/Octave
to 4.00dB/Octave. See Technical Specifications in section 15 for
further details .
Custom MLC LF Slope:
A slider that controls the slope of the LF section of the custom
MLC. Values of between 0 and 4 in 0.1 dB steps can be entered
here .
Custom MLC Knee Freq:
Controls the frequency where the LF custom slope stops and the
HF slope starts .
Custom MLC HF Slope:
A slider that controls the slope of the HF section of the custom
MLC. Values of between 0 and 4 in 0.1 dB steps can be entered
here .
Input Gain 1:
Controls the gain of the input 1 channel. Values of 0 to -80dB in
0 .1dB steps are allowed .
Input 1 mode:
The type of input required for input 1 . A drop down menu
selectable from Line, Mic or Mic + Phantom .
Input Gain 2:
Controls the gain of the input 2 channel. Values of 0 to -80dB in
0 .1dB steps are allowed .
Input 2 mode:
The type of input required for input 2 . A drop down menu
selectable from Line, Mic, Mic + Phantom, AES or DANTE if fitted.
Summary of Contents for d series
Page 1: ...D Series Installation Handbook User Guide www ampetronic co...
Page 2: ......
Page 45: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 43...
Page 46: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 44...
Page 47: ...INSTALLATION NOTES Ampetronic D Series Installation Handbook User Guide Page 45...
Page 48: ...Contents Copyright Ampetronic Ltd 2016 All rights reserved UP1 9001 4...