49
Electric Actuator
OMMG00012
Rev 12 – NOV 2019
Fig 16
Anti-Condensation Heater
11
Refit the motor strap through the slot in the terminal strip bracket and
around the motor and capacitor. Ensure the capacitor sits snugly against
the motor on the anti-vibration block.
12
Ensure that the actuator cover O ring is correctly fitted and undamaged.
13
Refit the actuator cover and secure with the socket head cap screws.
14
Energise the actuator power supply and control circuits and check for
correct operation.
4.8.9
Capacitor Replacement
WARNING
Lethal voltages are exposed when the actuator cover is removed,
presenting an electric shock hazard to personnel. Electrical power
supplies must be isolated from the actuator before the cover is
removed.
1
Switch off and isolate the actuator power supply.
Summary of Contents for 10GEF