Use only appropriate standard tools and equipment operated by qualified operators when installing, operating and
maintaining the filter.
When installation is required in hazardous environment sites, underground or high above ground, make sure that
the site design and the auxiliary equipment are appropriate and that installation procedures are carried out in
accordance with the relevant standards and regulations.
Ensure walking areas about the installation are slip free when wet.
Shipment and transporting
Shipping and transporting the filter must be done in a safe and stable manner and in accordance with the relevant
standards and regulations.
For shipping, lifting and positioning the filter, use only approved lifting equipment and authorized employees and
contractors.
Electricity
Electric wiring should be performed by an authorized electrician only, using standardized and approved components.
Install a
lockable
main power cut-off switch close to the control panel.
If due to site constraints, the control panel is installed without a clear line-of sight of the filter, an additional
lockable
power disconnect cut-off switch should be installed near each filter unit.
Installation of the filter should be performed so as to avoid direct water splashing on the electrical components or
on the control panel.
Pneumatics
Install a
lockable
main cut-off switch,
featured with a pressure release mechanism,
on the compressed air supply
line close to the control panel.
If the control panel is installed far away and there is no eye contact with the filter, a
lockable
compressed air cut-off
switch,
featured with a pressure release mechanism,
should be installed near each filter unit.
The user should make sure that the compressed air supplied to the filter never exceeds the maximum designated
pressure for this filter. An air-pressure reduction valve should be installed on the compressed air supply line
upstream of the filter’s pneumatic inlet port.
Hydraulics
Extra safety devices should be installed on hot water applications to avoid skin burn danger.
The user should install a manual Water Cut-off Valve next to the filter’s inlet port.
In cases where the downstream piping network downstream of the filter is pressurized an additional manual Water
Cut-off Valve should be installed next to the filter outlet port.
The user should make sure that the system includes a Pressure Release / Drainage Valve to enable release of
residual pressure prior to any maintenance procedure performed on the filter.
The user should make sure that the filter is never exposed to water pressure exceeding the maximum designated
pressure for this filter, if needed a Pressure Reduction Valve should be installed upstream of the filter’s water inlet
port.
Please note that the maximum working pressure indicated at the filter’s specifications table includes the pressure
caused by fluid hammer and pressure surge effects.
Summary of Contents for AMF-36K
Page 16: ...Figure 25 ...
Page 17: ...AMF 36K HMI 08 2013 Page 17 of 71 ...
Page 23: ...AMF 36K HMI 08 2013 Page 23 of 71 1 3 ...
Page 65: ...AMF 36K HMI 08 2013 Page 65 of 71 5 3 Control cabinet drawings ...
Page 66: ...AMF 36K HMI 08 2013 Page 66 of 71 ...
Page 67: ...AMF 36K HMI 08 2013 Page 67 of 71 ...
Page 68: ...AMF 36K HMI 08 2013 Page 68 of 71 ...
Page 69: ...AMF 36K HMI 08 2013 Page 69 of 71 ...