3.8.5 Tools screens
Language Screen
This screen allows the operator to:
Select the desired HMI language.
Press the desired national flag and press OK.
Note:
please refer to chapter 2.5
Changing the HMI language
for
a complete explanation on the multilingual feature of the HMI
system.
Valves 1 Screen
This screen allows the operator to set the:
Inlet / Outlet Closing Delay
– Set the delay for closing the inlet
and outlet valves. (Default value - 10 seconds.)
Duration of Filter Draining
– Set the time required to completely
emptying the filter. (Default value - 60 seconds.)
Flush Valve Closing Delay –
Set the delay for closing the Flush
Valve (V5). (Default value - 10 seconds.)
Drain Valve Closing Delay –
The delay for closing the Drain Valve
(V4). (Default value - 10 seconds.)
Duration of Filter Refilling -
Set the time required to fill the filter
after flushing. (Listen to the noise of the exhaust air in order to
determine the end of the filling process). (Default Value - 40
seconds.)