1. Introduction & How to use this manual
1.1
Using this manual
This manual describes the end-user operation procedures of Amiad’s AMF 36K filter. For broadening the user’s general
knowledge a general description of Amiad’s micro-fiber filtration technology and some basic information on installation is
also provided.
This manual does not replace the Technicians’ Installation, Service and Maintenance Manuals and it should not be used
for any task other than the regular operation of the filter.
Before operating the filter please read this manual carefully. Make sure that:
You are familiar with the safety instructions
(Chapter 1.2)
You understand the basics of the Micro-fiber filtration technology
(Chapter 1.3)
You know how to use the control panel
(Chapter 3)
1.2
Safety instructions
General Safety Instructions
Amiad filtration products always operate as components in a larger system. It is essential for the system designers,
installers and operators to comply with all the relevant safety standards.
Prior to installation, operation, maintenance or any other type of action carried out on the filter, read carefully the
safety, installation and operation instructions.
During installation, operation or maintenance of the filter all conventional safety instructions should be observed in
order to avoid danger to the workers, the public or to property in the vicinity.
Please note: The filter enters into a flushing mode automatically, without prior warning.
No change or modification to the equipment is permitted without a written notification given in advance by the
manufacturer or by its representative, on the manufacturer’s behalf.
Always observe standard safety instructions and good engineering practices whilst working in the filter’s vicinity.
Use the filter only for its intended use as designed by Amiad, any misuse of the filter may lead to undesired damage
and may affect your warranty coverage. Please consult with Amiad prior to any non-regular use of this equipment.
Installation
General
Install the filter according to the detailed Installation Instructions provided with the filter by the manufacturer and
according to the description given in this manual.
Make sure to leave enough clearance so as to enable easy access for future treatments and safe maintenance
operations.
The user should arrange suitable lighting at the area of the filter to enable good visibility and safe maintenance.
The user should arrange suitable platforms, ladders and safety barriers to enable easy and safe access to the filter
without climbing on pipes and other equipment. The user should verify that any platform, barrier, ladder or other
such equipment is built, installed and used in accordance with the relevant local authorized standards.
Check and re-tighten all bolts during commissioning and after the first week of operation.
Summary of Contents for AMF-36K
Page 16: ...Figure 25 ...
Page 17: ...AMF 36K HMI 08 2013 Page 17 of 71 ...
Page 23: ...AMF 36K HMI 08 2013 Page 23 of 71 1 3 ...
Page 65: ...AMF 36K HMI 08 2013 Page 65 of 71 5 3 Control cabinet drawings ...
Page 66: ...AMF 36K HMI 08 2013 Page 66 of 71 ...
Page 67: ...AMF 36K HMI 08 2013 Page 67 of 71 ...
Page 68: ...AMF 36K HMI 08 2013 Page 68 of 71 ...
Page 69: ...AMF 36K HMI 08 2013 Page 69 of 71 ...