BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
59
This program sets the maximum charge capacity that will be supplied to the
battery during charge. If the deltapack voltage is not detected nor the safety
time expired by any reason, this feature will automatically stop the process at
the selected capacity value.
The beep sounds at every time pressing the buttons to confirm your action. The
beep or melody sounded at various times during operation to alert different
mode changes. These audible sounds can be on or off.
This program monitors the voltage of input battery. If the voltage drops below
the value, you set the operation forcibly terminated to protect the input
battery.
This screen shows the external and internal temperature.
Press the Start/Enter button for 3 more than seconds to load the factory set.
Capacity
Current
Safety Time
2000mAh
2,0A
(2000/2,0 = 1000) / 11,9 = 84 Minutes
3300mAh
3,0A
(3000/3,0 = 1100) / 11,9 = 92 Minutes
1000mAh
1,2A
(1000/1,2 = 833) / 11,9 = 70 Minutes
Capacity Cut-Off
ON
5000mAH
Key Beep
ON
Buzzer
ON
Input Power Low
Cut-Off 11.0V
Ext. Temp 0C
Int. Temp 37C
DEC. INC.
DEC. INC.
DEC. INC.
DEC. INC.
LOAD FACTORY SET