DISCHARGING OF NIMH/NICD BATTERY
Set the discharge current on the left side and the final voltage on the right side.
The range of the discharge current is 0.1-5.0A, the range of the final voltage is
0.1-25.2V. Press the START/ENTER button for more than 3 seconds to start the
program.
You can press the START/ENTER button to change the discharge current,
press the START/ENTER button again to save the value, press the BATT
TYPE/STOP button to end the discharge process. The end of the discharge
process is indicated by an acoustic signal.
CHARGE/DISCHARGE & DISCHARGE/CHARGE CYCLE OF NIMH/NICD BATTERIES
On the left side you can set the sequence and on the right side the number of
cycles. The range of the cycle number is 1-5.
Press the BATT TYPE/STOP button to stop the programme, you can press the
Inc. or Dec. buttons to change the charging current, the sound indicates the
end of the program.
Start
Enter
Batt type
Stop
>3 seconds
DEC. INC.
Battery
type
- +
NiMH DISCHARGE
1.0A CUT:6.0V
Discharge
current
Battery
type
Battery
voltage
Elapsed
time
Discharged
capacity
NiMH 1.0A 7.42V
DSC 022:45 00379