BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
58
SYSTEM SET UP
It will be operated with the default value of the essential user settings when it is connected to a DC 11~18V battery at
the first time. The screen displays the below information in sequence and the user can change the value of parameter on
each screen. Press START/ ENTER button to make it blink then change the value by press Dec. or Inc. button. The value
will be stored by press START/ENTER button again.
User Set up screen.
The battery is on the cyclic process of charge and discharge can often become
warm after charge or discharge period. The program can insert a time delay to
occur after each charge and discharge process to allow the battery adequate
time to cool down before being subjected to the next process. The value ranges
from 1 to 60 minutes.
When you start a charge process, the integral safety time automatically starts
running at the same time. This is programmed to prevent overcharge the
battery if it proves to be faulty, or if the termination circuit cannot detect the
battery full. The value for the safety time should be generous enough to allow a
full charge of the battery.
Safe time Calculation
When charging NiMH or NiCD batteries, divide the capacity by current, then
divide the result by 11.9, set this number as the value for safety time setting.
Wenn das Ladegerät bei diesem dieser Schwelle anhält, werden etwa 140 %
der Kapazität in die Batterie eingespeist worden sein.
PROGRAM SELECT
SYSTEM SET
Rest Time
CHG
˚
DCHG 10Min
SAFETY TIME
ON
120Min
DEC. INC.
DEC. INC.
DEC. INC.