Features and Specifications
DLM-E 3kW & 4kW Series Power Supplies
1-4
M362000-01 Rev E
1.4.2
4 kW DLM–E Electrical Specifications
9
Model 5–450
8–450
16–250 22-180 32–125 40–100 60–66 80–50 150–26 300–13 600–6.6
Output Ratings:
Output Voltage
Output Current
Output Power
0–5V
0–450A
2250W
0–8V
0–450A
3600W
0–16V
0–250A
4000W
0-22V
0-180A
4000W
0–32V
0–125A
4000W
0–40V
0–100A
4000W
0–60V
0–66A
3960W
0–80V
0–50A
4000W
0–150V
0–26A
3900W
0–300V
0–13A
3900W
0–600V
0–6.6A
3960W
Line Regulation:
10
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
5 mV
450 mA
6 mV
450 mA
10 mV
250 mA
13 mV
180mA
18 mV
125 mA
22 mV
100 mA
32 mV
66 mA
42 mV
50 mA
77 mV
26 mA
152 mV
13 mA
302 mV
7 mA
Load Regulation:
11
Voltage (0.05% of Vmax+2mV)
Current (0.1% of Imax)
5 mV
450 mA
6 mV
450 mA
10 mV
250 mA
13 mV
180mA
18 mV
125 mA
22 mV
100 mA
32mV
66 mA
42 mV
50 mA
77 mV
26 mA
152 mV
13 mA
302 mV
7 mA
Meter Accuracy:
Voltage (0.5% Vmax+1count)
Current (0.75% Imax+1count)
0.04V
5A
0.05V
5A
0.09V
3A
0.2V
3A
0.3V
1A
0.3V
0.9A
0.4V
0.6A
0.5V
0.5A
0.9V
0.3A
1.6V
0.11A
3.1V
0.06A
Preview Accuracy
Voltage (0.5% Vmax+1 count)
Current (1.0% Imax+1 count)
0.04V
6A
0.05V
6A
0.09V
4A
0.2V
3A
0.3V
1.4A
0.3V
1.1A
0.4V
0.8A
0.5V
0.6A
0.9V
0.4A
3V
0.14A
4V
0.08A
OVP Adjustment Range
(6% to 110% Vmax)
0.3–
5.5V
0.4–
8.8V
0.8–
17.6V
1.1-
24.2V
1.6–35V 2–44V 3–66V 4–88V
7.5–
165V
15–
330V
30–
660V
Output Noise and Ripple (V)
RMS
p–p (20 Hz–20 MHz)
12 mV
100
mV
12
12 mV
100
mV
12
10 mV
100
mV
12
10 mV
100
mV
12
10 mV
100
mV
12
10 mV
100
mV
12
15 mV
100 mV
15 mV
120 mV
30 mV
100 mV
60 mV
150 mV
100 mV
300 mV
Stability:
13, 14
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
3 mV
225 mA
4 mV
225 mA
8 mV
125 mA
11 mV
90 mA
16 mV
63 mA
20 mV
50 mA
30 mV
33 mA
40 mV
25 mA
75 mV
13 mA
150 mV
6.5 mA
300 mV
3.3 mA
Temperature Coefficient:
15
Voltage (0.02% of Vmax)
Current (0.03% of Imax)
1 mV
135 mA
1.6 mV
135 mA
3.2 mV
75 mA
4.4 mV
54 mA
6 mV
38 mA
8 mV
30 mA
12 mV
19.8 mA
16 mV
15 mA
30 mV
7.8 mA
60 mV
3.9 mA
120 mV
2.0 mA
Maximum Remote Sense
Line Drop Compensation per line
16
2V 2V 2V 2V 5V 5V 5V 5V 5V 5V 5V
9.
Specifications are warranted over a temperature range of 0–50°C with default local sensing.
From 50–70°C, derate output 2% per °C.
From 40–70°C, derate output 2% per °C below 190 VAC with single or three–phase inputs.
10.
For input voltage variation over the AC input voltage range, with constant rated load.
11.
For 0–100% load variation, with constant nominal line voltage.
12.
Typical P–P noise and ripple is 50 mV.
13.
Maximum drift over 8 hours with constant line, load, and temperature, after 15 minute warm–up (30 minute warm–up
for 5V, 8V, and 16V models).
14.
Current accuracy for 5V, 8V, and 16V models is 1% typical.
15.
Change in output per °C change in ambient temperature, with constant line and load.
16.
Line drop subtracts from the maximum available output voltage at full rated power.
Summary of Contents for Sorensen DLM-E
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...viii M362000 01 Rev E This page intentionally left blank...
Page 8: ...x M362000 01 Rev E This page intentionally left blank...
Page 10: ...xii M362000 01 Rev E This page intentionally left blank...
Page 12: ...xiv M362000 01 Rev E This page intentionally left blank...
Page 18: ......