Maintenance and Troubleshooting
DLM-E 3kW & 4kW Series Power Supplies
5-2
M362000-01 Rev E
5.2.2
Troubleshooting at the Operation Level
Use the checks in Table 5–1 to ensure the DLM–E Series power supply is configured and
connected for default operation at the front panel. If you need any further troubleshooting, call
customer service.
Symptom
Check
Further Checks and Corrections
No output and the
display is blank
Is input voltage within specified
range?
Connect to appropriate voltage
source. See
.
Power switch ON?
Turn on power.
Internal circuit?
See your service technician.
No output but the
display lights
OVP LED lit?
See
.
Front panel S/D LED lit?
See
.
OTEMP LED lit?
See
.
Current limit set to zero?
See
.
Voltage control set to zero?
See
.
REM LED lit?
See
.
Is front panel ON LED lit?
Connect unit to AC supply in specified
range. See
.
Internal circuit.
See your service technician.
Output not adjustable
Is unit in current limit mode?
(Green Current Mode LED lit.)
Turn current knob clockwise to
increase current limit. Reduce load if
current is at maximum. See
Section 3.2.1
Is unit in REMOTE mode?
(Green REM LED lit.)
See
.
Is unit in LOCK mode?
(Green LOCK LED lit.)
See
.
Is unit at maximum voltage or
current limit?
Reduce load for lower voltage or
current requirement.
Output voltage
fluctuating
or regulation poor
Is unit at current limit?
Increase current limit setting or reduce
load. See
Section 3.2.1
Is input voltage within specified
range?
Connect to appropriate AC voltage
source. See
.
Are sense lines connected?
See
and
.
Is unit under remote analog
control?
Ensure program source is stable.
Internal circuit.
See your service technician.
Output oscillating
Internal circuit.
See your service technician.
Table 5–1. User Diagnostics
Summary of Contents for Sorensen DLM-E
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...viii M362000 01 Rev E This page intentionally left blank...
Page 8: ...x M362000 01 Rev E This page intentionally left blank...
Page 10: ...xii M362000 01 Rev E This page intentionally left blank...
Page 12: ...xiv M362000 01 Rev E This page intentionally left blank...
Page 18: ......