19
3.5 Factory Reset Procedures
Newer Amcrest model DVRs, such as the XVR or S5 models, will have a different factory reset process than its
previous counterparts.
To begin the process, you will need to remove the DVR cover. Use a Phillips head screwdriver to remove the four
screws on the back and sides of the DVR. Once the screws have been removed, lift the lid to expose the DVR's
motherboard.
On the motherboard you will notice a small black button. This is the factory reset switch for your DVR:
To factory reset the DVR, unplug the DVR from power. Once power is removed from the unit, press and hold the
factory reset switch for 4 - 5 seconds. Continue holding the reset switch and plug the DVR's power supply back into
the unit, you will hear a beep.
Continue holding the reset switch and allow the DVR to initialize for 20 - 30 seconds and then release the switch.
The DVR will be set to default and will show the DVR initialization screen. For more information on the DVR
initialization screen, refer to section
4.2 DVR Initialization
.
4.
Overview of Navigation and Controls
4.1 Startup and Shut down
4.1.1 Startup
Before initial startup, please make sure: