20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
INSTALLING THE SD17060E
4
37
Connecting the Motor (continued)
Motor Wiring (continued)
Figure 4.3 Motor Wiring
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
8
LEAD
MOTOR
Eight Lead Series Connected
Motor Case
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
8
LEAD
MOTOR
Eight Lead Parallel Connected
Motor Case
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
6
LEAD
MOTOR
Six Lead Series Connected
Motor Case
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
6
LEAD
MOTOR
Six Lead Center Tap Connected
Motor Case
INTERLOCK
B CTAP
B
B
EARTH GND
A CTAP
INTERLOCK
A
A
4
LEAD
MOTOR
Four Lead Connected
Motor Case
SHIELDS
SHIELDS
SHIELDS
SHIELDS
SHIELDS
Interlock Jumper
Interlock Jumper
Interlock Jumper
Interlock Jumper
Interlock Jumper
Motor Case
Motor Case
Motor Case
1)
2) Motor connections should be tight.
Loose connections may lead to
arcing which will heat the connector.
Phoenix Contact specifies a tighten-
ing torque of 4.4 to 5.4 lb-in. (0.5 to
0.6 Nm)
Refer to the torque vs. speed curves
on your motor's specifications sheet
to determine if you should wire the
motor to the SD17060E in series,
parallel, or center-tap configuration.