20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
PROFINET Protocol
PROFINET N
ETWORK
C
ONFIGURATION
97
MRP Installations
At this point, the NR60E2 is configured and ready to use. If you are using the unit in a redundant, ring based,
network that uses the Media Redundancy Protocol (MRP), continue with the following instructions.
7.9 Configure the NR60E2 as an MRC
The NR60E2 functions as a Media Redundancy Client (MRC) in an MRP network.
1) Switch to Topology view and drag the additional connections between the appropriate ports.
2) Click on the NR60E2 icon to select it. In the Inspector window, select
Advanced o> Media
redundancy
. Use the “MRP domain:” drop down menu to select the appropriate domain. Use the “Media
redundancy role:” drop down menu to select “Client”.
3) Continuing in the Inspector window, select
Advanced o> Port 1 +> Port interconnection
. Under
“Partner port:”, the partner port you assigned to the port when you drew the topology is shown. If you do
not know which port will be the partner port in the actual installation, you can use the drop down menu to
select “Any partner”.
4) If need be, repeat step 3 for Port 2 of the NR60E2.
5) Continue configuring the rest of the devices on the network before compiling the project and downloading
it to the CPU.
Media Redundancy Protocol (MRP) installations require that the NR60E2 be
installed in a ring topology. In these applications, both Ethernet ports are used
when wiring the ring, daisy chaining from one unit in the ring to the next. The
steps below covers typical software configuration that must also be completed.
Summary of Contents for NR60E2
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual E2 Technology E2 Technology Manual 940 0D161...
Page 6: ...TABLE OF CONTENTS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 20: ...NR60 SPECIFICATIONS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Page 44: ...PROTOCOL SPECIFIC INFORMATION NR60E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Page 52: ...IMPLICIT COMMUNICATIONS WITH AN EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 52 Notes...
Page 58: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 58 Notes...
Page 70: ...CIP POSITION SENSOR OBJECT EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Page 90: ...PROFINET CYCLIC DATA FORMATS PROFINET Protocol ADVANCED MICRO CONTROLS INC 90 Notes...
Page 98: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...