PROFINET Protocol
PROFINET N
ETWORK
C
ONFIGURATION
93
7.4 Add the NR60E2 to the PROFINET Network (continued)
5) Right click on the NR60E2 icon and select “Properties” from the pop up menu. The Inspector window will
open at the bottom of the screen. Under the “General” tab, select the “
General” heading. You can rename
the NR60E2 by changing the Name: field.
6) Under the “
PROFINET interface [x1]” heading, select “Ethernet addresses”. Under the IP protocol
section, set the desired IP address and subnet mask for the NR60E2.
Figure T7.3 NR60E2 IP Addressing